GUNS AND CABLES ASSEMBLIES

A variety of Lincoln 10' (3.0m) or 15' (4.6m) gun and
cable assemblies are available for use with the LN-15,
including the Magnum™ models for GMAW, K126 or
K115 models for Innershield®, and more.

The LN-15 comes factory equipped with a K1500-2
gun receiver bushing, designed for guns having a
Tweco™ #2-#4 connector. Many other guns can easi-
ly be used with the LN-15 with other K1500 series gun
connection kits.

Gun Cable Connection to the Feeder
Lay the cable out straight. Insert the connector on the
welding conductor cable into the brass bushing on the
front of the wire drive unit. Keep the all mating sur-
faces clean. Make sure it is fully seated and tighten
the thumb screw.

Connect the control cable plug into the 5 pin recepta-
cle on the front panel of the wire feeder.

ELECTRODE POLARITY

The LN-15 automatically adjusts for positive and neg-
ative polarity. When welding with negative polarity
procedures, the voltmeter will display a "-" sign; exam-
ple "-23.6" Volts.

CONTROL CABLE CONNECTIONS

For Control Cable model, attach the control cable from
the LN-15 to power source. Do not use more than 150
ft (45 m) of cable.

A-3

INSTALLATION

LN-15 CONTROL CABLE MODEL

A-3

CONNECTION DIAGRAM, CONTROL
CABLE MODELS

( See Figure A.1)

FIGURE A.1

Table A.2 Trigger Connector J1 (5 Pin)
PIN

Lead #

Function

A

556

Trigger

B

-

Not used

C

554

Trigger/ 83%
Procedure ground

D

555

83% Procedure

E

554

Trigger/ 83%
Procedure ground

Table A.3 Control Cable Receptacle (8 Pin
PIN

Lead #

Function

A

41

42 VAC

B

42

42 VAC

C

2

Output Control (trigger)

D

4

Output Control (trigger)

E

21

Work Sense Lead

F

75

Remote Voltage Control

G

76

Remote Voltage Control

H

77

Remote Voltage Control

8 Pin Control Cable Receptacle

5 Pin Trigger Connector

WELDING CABLE
(ELECTODE)

WELDING CABLE (WORK)