E-2

TROUBLESHOOTING

E-2

LN-15 CONTROL CABLE MODEL

Observe all Safety Guidelines detailed throughout this manual

If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact your

Local Lincoln Authorized Field Service Facility

for technical troubleshooting assistance before you proceed.

CAUTION

PROBLEMS

(SYMPTOMS)

POSSIBLE AREAS OF

MISADJUSTMENTS

RECOMMENDED

COURSE OF ACTION

Major physical or electrical damage
is evident when the sheet metal cov-
ers are removed.

The wire drive stops feeding wire
after about 10 seconds.

No shielding gas flow.

The shielding gas turns on sporadi-
cally, or remains on all the time.

The Wire Feed Speed Range is only
50 - 601 in/min ( 1.3 - 15.3 m/min).

1. Contact your local authorized

Lincoln Electric Field Service facil-
ity for technical assistance.

1. The motor has exceeded the cur-

rent rating.

2. Check to make sure the electrode

slides easily through the liner of
the gun.

3. Verify that the spindle brake is not

set too tight.

4. For best results, use only Lincoln

electrodes.

5. Wait 10 minutes for the wire feed-

er to cool.

1. The gas bottle empty.

2. The gas hose is cut or clogged.

3. The flow meter valve is closed.

4. The gas solenoid has failed

5. The feed head board has failed.

1. The pressure in the gas line is

exceeding 80 psi (5.5 bar)

2. The gas solenoid has failed.

1. The 83% wire feed speed dual

procedure is activated with the
high speed gear. Turn off the dual
procedure switch to return to the
full wire feed speed range.

If all recommended possible areas
of misadjustment have been
checked and the problem persists,

Contact your local Lincoln
Authorized Field Service Facility.