DIP Switch Settings and Locations

DIP switches on the P.C. Boards allow for custom
configuration of the Power Wave

®

. To access the DIP

switches:

• Turn off power at the disconnect switch.

------------------------------------------------------------------------

• Remove the top four screws securing the front

access panel.

• Loosen, but do not completely remove, the bottom

two screws holding the access panel.

• Open the access panel, allowing the weight of the

panel to be carried by the bottom two screws. Make
sure to prevent the weight of the access panel from
hanging on the harness.

• Adjust the DIP switches as necessary.
• Replace the panel and screws, and restore power.

Control Board DIP Switch:

Switch 1 = Object Instance LSB1 (see table 3)

Switch 2 = Object Instance MSB2 (see table 3)
Switch 3 = Equipment Group 1 Select
Switch 4 = Equipment Group 2 Select
Switch 5 = Equipment Group 3 Select
Switch 6 = Equipment Group 4 Select
Switch 7 = reserved for future use
Switch 8 = work sense lead

1 LEASE SIGNIFICANT BIT
2 MOST SIGNIFICANT BIT

Switch 8 work sense lead

Off

work sense lead not connected

On

work sense lead connected

Feed Head Board DIP Switch:

Switch 1 = Object Instance LISE (see table 3)
Switch 2 = Object Instance msp (see table 3)
Switch 3 = Equipment Group 1 Select
Switch 4 = Equipment Group 2 Select
Switch 5 = Equipment Group 3 Select
Switch 6 = Equipment Group 4 Select
Switch 7 = negative polarity switch

Switch 7

Electrode polarity

Off

Positive (default)

On

negative

Switch 8 = high speed gear

Switch 8

Wire drive gear

Off

Low speed gear (default)

On

high speed gear

DeviceNET/Gateway Board DIP Switch:

Bank (S1):

Switch 1 = Object Instance LISE (see table3)
Switch 2 = Object Instance msp (see table 3)
Switch 3 = Equipment Group 1 Select
Switch 4 = Equipment Group 2 Select
Switch 5 = Equipment Group 3 Select
Switch 6 = Equipment Group 4 Select
Switch 7 = Reserved for future use
Switch 8 = Reserved for future use

TABLE 3

Object Instance
Switch 2 switch 1 Instance

Off

Off

0 (default)

Off

On

1

On

off

2

On

on

3