B-4

OPERATION

POWER WAVE

®

655/R

B-4

CASE FRONT CONTROLS

All operator controls and adjustments are located on
the case front of the Power Wave

®

. (See Figure B.1)

1. POWER SWITCH: Controls input power to the

Power Wave

®

.

2. STATUS LIGHT: A two color light that indicates

system errors. Normal operation is a steady green
light. Error conditions are indicated per table 4.

NOTE: The robotic Power Waveʼs

®

status light will

flash green, and sometimes red and green, for up to
one minute when the machine is first turned on. This
is a normal situation as the machine goes through a
self test at power up.

TABLE 6

Light

Condition

Steady Green

Blinking
Green

A l t e r n a t i n g
Green and
Red

Steady Red

Blinking Red

Meaning

System OK. Power source communicating normal-
ly with wire feeder and its components.

Occurs during a reset, and indicates the PW-
655/R is mapping (identifying) each component
in the system. Normal for first 1-10 seconds
after power is turned on, or if the system con-
figuration is changed during operation.

Non-recoverable system fault. If the PS
Status light is flashing any combination of
red and green, errors are present in the PW-
655/R. Read the error code before the
machine is turned off.

Error Code interpretation through the Status
light is detailed in the Service Manual.
Individual code digits are flashed in red with
a long pause between digits. If more than
one code is present, the codes will be sepa-
rated by a green light.

To clear the error, turn power source off, and
back on to reset. See Troubleshooting
Section.

Not applicable.

Not applicable.

3. HIGH TEMPERATURE LIGHT (thermal overload):

A yellow light that comes on when an over temper-
ature situation occurs. Output is disabled until the
machine cools down. When cool, the light goes out
and output is enabled.

4. 10 AMP WIRE FEEDER CIRCUIT BREAKER:

Protects 40 volt DC wire feeder power supply.

5. 10 AMP AUXILIARY POWER CIRCUIT BREAKER:

Protects 110 volt AC case front receptacle auxiliary
supply.

6. LEAD CONNECTOR S2 (SENSE LEAD)

7. 5-PIN ARC LINK S1

8. 5-PIN DEVICENET CONNECTOR S5

9. I / O CONNECTOR

10. NEGATIVE STUD

11. INTERFACE CONNECTOR S6

12. POSITIVE STUD

13. AUXILIARY OUTPUT

-

+

POWERWAVE

Case Front Layout

Power Wave 655/R (Domestic/Canadian Version)

1

3

2

11

12

4

13

5

9

10

8

7

6

®

FIGURE B.1