Procedure: Enabling Arc Production Monitor

Appendix B. FANUC Robots

IM8002

Power Wave® Manager User Manual

B.13

Figure 11.5 Arc Analog Meter

While welding, these meters display the actual values of the selected parameters. At the end of the weld,

the WeldScore™ meter displays the average value for the previous weld.

Proxy Server Function for CheckPoint™ Cloud Server Data Storage

When the robot controller Ethernet Port 1 is connected to a network that allows access to the Internet,

messages from the Lincoln Power Wave® Welding Power Source can be forwarded to a user-specified Proxy

Server, which forwards these messages to the CheckPoint™ cloud server that acts as the repository for

welding data.
The Proxy Server option appears in the collection of Host Communication options available on the Teach

Pendant and is selected by pressing MENU > SETUP > Host Comm and then selecting the item labeled

Proxy Server (Figure 11.6).

Figure 11.6 Proxy Server Function