Lincoln Electric IM8002 POWER WAVE MANAGER User Manual

Page 36

Advertising
background image

Chapter 6. Power Source Settings

Calibration

6.2

Power Wave® Manager User Manual

IM8002

The following is the recommended procedure for calibrating your power source:

Procedure

Details

1.

Attach Welding Power Source output cables

to a 300A/30V resistive grid load.

2.

Open Power Wave® Manager.

3.

Connect to the power source.

4.

Display the Calibration section.

5.

Click the Turn output ON button.

The Turn Output ON button enables the output

of the Welding Power Source. When you turn

the output on, the indicator will begin to flash red

( ), and values will appear under Feedback for:

Output amperage, Output voltage, Capacitor

voltages and Voltage sense location.

6.

Use the plus and minus icons ( and ) to

the right of Amperage adjust (Figure 6.1) to

calibrate the Welding Power Source to the

value you set in Power Wave® Manager.

This adjusts the actual measured values on the

Welding Power Source to match Power Wave®

Manager.

7.

Use the plus and minus icons ( and ) to

the right of Voltage adjust (Figure 6.1) to

calibrate Power Wave® Manager to the

Welding Power Source.

This adjusts the feedback in Power Wave®

Manager to match the Welding Power Source.

STOP |

Do not calibrate voltage at voltages

greater than 50V.

8.

Click the Turn output OFF button.

The Turn Output OFF button disables the Welding

Power Source’s output.

Advertising