2.2.2.5.1 ALARM SETUP

Move the cursor to【ALARM SETUP】(Icon highlighted when selected),press【Enter】

to access setting interface.

I/O CHANNEL: Each channel corresponds an I/O status, which means when an alarm is

triggered, it will activate the corresponding channel to start alarm recording.

N.O:indicate I / O input level from high to low
N.C:indicate I / O input level from low to high
HDD LOSS:ON: means it will trigger an alarm if there is no HDD, and a 【H】will be displayed
on the left bottom of channel 1 in the live view
HDD SPACE:ON:If the space is less than 500M, a remark will appear in live view:Not enough
space, please change HDD after shutdown.
VIDEO LOSS:ON:when one channel has no video input, it will display “video loss” in live view.
ALARM MANAGE:Includes three options, alarm output, buzzer and post REC.
OUTPUT:When an alarm is triggered, the alarm output time will be:

0 second、10 seconds, 20 seconds, 40 seconds and 60 seconds

BUZZER:Buzzer calling time setup when alarm is triggered: 0 second,10
seconds,20 seconds,40 seconds and 60 seconds

POST REC.:Post recording time setup: 30 seconds,1 minute,2 minutes and 5
minutes

PRE REC:Pre-recording time is fixed as10 seconds.

2.2.2.5.2 SYSTEM INFO

Move the cursor to【SYSTEM INFO】(Icon highlighted when selected),press【Enter】to

access setting interface. This interface mainly displays system hardware features and firmware
versions; includes : device type, software version, MAC address, serial number.