Autostart CT-1010 User Manual

Page 5

Advertising
background image

Installation Guide

P. 5

After selecting the function, press one of the corresponding buttons to select the option.

for Option 1,

for Option 2,

for Option 3;

for Option 4;

+

for Option 5.

+

for Option 6.


Programming Options

MODE 1

* INDICATES DEFAULT SETTING

FUNCTION 1 – Ignition-controlled door locks

OPTION 1*

Ignition lock disabled

OPTION 2

Ignition lock enabled

OPTION 3

Ignition unlock ONLY

OPTION 4

Ignition lock ONLY

FUNCTION 2 – Door lock pulse timing

OPTION 1*

7/10-sec. lock/unlock pulses

OPTION 2

4-sec. lock/unlock pulses

OPTION 3

7/10-sec. lock pulse and two ¼ -sec. unlock pulses

OPTION 4

1/10-sec. lock/unlock pulses

FUNCTION 3 – AUX3 Programming – Press the

button for 4 seconds (for options 1 through 5)

OPTION 1*

Constant while button is pressed

OPTION 2

Toggle ON – Toggle OFF

OPTION 3

60-second pulse

OPTION 4

1-second pulse with Unlock pulse and Disarm pulse

OPTION 5

1-second pulse with Disarm pulse. Once the Trunk is closed, Arm pulse after 5-sec. delay.

OPTION 6

Disarm function (with

UNLOCK

button)

FUNCTION 4 – AUX2 Programming – Use with

button (for options 1 through 4 and car finder)

OPTION 1*

Constant while button is pressed – Car finder disabled

OPTION 2

Toggle ON – Toggle OFF with 30 seconds timeout or until ignition ON – Car finder

disabled

OPTION 3

30-second pulse - Car finder disabled

OPTION 4

60-second pulse - Car finder disabled

OPTION 5

Retain accessory output - Car finder enabled

OPTION 6

Arm output - Car finder enabled

FUNCTION 5 – AUX1 Programming

OPTION 1*

Priority door

OPTION 2

Dome light output for 60 seconds

OPTION 3

Arm output

OPTION 4

Disarm output

OPTION 5

Retain accessory output

Advertising