Airvantage servicing - check valve – SANDPIPER RHDB2 Metallic User Manual

Page 32

Advertising
background image

rhdb2dl1sm-rev0614

Model RHDB2 Page 30

AirVantage - Check Valve Assembly

To service the check valve, first shut off and bleed the air being supplied to the pump. For safety

purposes the air supply line should be disconnected from the pump. Then shut off the suction

and discharge lines to the pump. Bleed the pressure from the pump suction and discharge

lines and remove the lines from the pump. During the servicing of the AirVantage, consult the

“AirVantage Composite Repair Parts Drawing” (Page 11)

Step #1: Remove the Patch Cable

Twist the ribbed portion of the patch cable connector in the counterclockwise direction, until it

un-threads from the connector. The cable can be either be removed from the intermediate or

from the control module.

Step #2: Remove the AirVantage from the Pump

Use a ½” socket and remove the four 5/16 x 5 ½ cap screws that hold the AirVantage to the

pump. Remove the two chamber bolts/nuts that are holding the right side bracket to be able to

remove the right bracket and the AirVantage unit from the pump. Be sure to support the weight

of the AirVantage while removing the last cap screw. After the AirVantage is removed from the

pump, set the unit down on the plastic cover located on the bottom. Inspect the o-ring between

the poppet valve and adapter plate for damage.

Step 3: Remove the Check Valve from the Pump

Use a ½” socket and remove the four 5/16 x 2 ½ cap screw that holds the check

valve to the pump.

Step 4: Inspect Check Valve

Using a 1 ¼” open socket wrench, remove the cartridge valve. Inspect o-rings and mechanism

for any signs of wear, degradation, or damage. If any is present, replace with new cartridge valve

assembly. Remove any remaining fluid contamination on inside of body and/or cartridge valve.

Be careful not to lose the large and small o-rings on either face of the check valve body.

Step 5: Re-assembly of Check Valve

Apply a thin layer of white lithium grease to the threads on the valve cartridge. Insert cartridge

valve into body and hand-tighten being careful not to pinch o-ring. Using a 9” torque wrench

with crow-foot, torque cartridge vale to 250 in-lbs. Re-apply o-rings, as necessary, to both faces

of check valve. After applying Blue Loctite 248, 222 (or equivalent) secure check valve back to

pump with four 5/16 x 2 ½ cap screws, re-torque to 90 in-lbs.

To secure the AirVantage, re-install the four 5/16 x 5 ½ cap screws, torquing to 90 in-lbs. Re-

install Patchcable.