Warning, Grounding the pump – SANDPIPER RHDB2 Metallic User Manual

Page 33

Advertising
background image

rhdb2dl1sm-rev0614

Model RHDB2 Page 31

This 8-foot long (244 centimeters) Ground Strap, part number

920-025-000, can be ordered as a service item.

To reduce the risk of static electrical sparking, this pump must

be grounded. Check the local electrical code for detailed

grounding instruction and the type of equipment required.

Grounding The Pump

Take action to prevent static

sparking. Fire or explosion can

result, especially when handling

flammable liquids. The pump,

piping, valves, containers or other

miscellaneous equipment must

be grounded.

WARNING

One eyelet is installed to a true earth ground.

(Requires a 5/16 or 8mm maximum diameter bolt)

One eyelet is fastened to the pump hardware.

Advertising