Airvantage troubleshooting continued – SANDPIPER RS30 Non-Metallic User Manual

Page 11

Advertising
background image

rs30nmdl2sm-rev0614

Model RS30 Non-Metallic Page 9

AirVantage Troubleshooting Continued

AirVantage RESETS AND ENTERS LEARN MODE TOO FREQUENTLY

What to Check:

• Check for excessive varying environmental pumping conditions

(changing head or suction)

• Check ice buildup in exhaust area

• Inspect sleeve and spool set for damage

• Make sure patch cable plug is connected and locked

Corrective Action:

• Consult Factory After Sales Support Team

PUMP STALLS, RESETS, LEARNS, SEEKS AND REPEATS

What to Check:

• Make sure patch cable plug is connected and locked

• Check ice buildup in exhaust area

Corrective Action:

• Consult Factory After Sales Support Team

PUMP MOVES OUT OF STEADY STATE AND NEVER

ATTEMPTS TO RELEARN (LED ON)

What to Check:

• Make sure patch cable plug is connected and locked

• Cycle the power off/on to the control module

Corrective Action:

• Consult Factory After Sales Support Team

• Cycle the power switch on the control module off/on

WHAT TO DO IN THE EVENT OF A DIAPHRAGM FAILURE

If a diaphragm failure has been detected in pumps fitted with AirVantage,

see page 5 for shut-down procedure.

What to Check:

• Has product migrated to the sensor?

Corrective Action:

• If the sensor has been submerged in product, the sensor will need to be

replaced. Consult the AirVantage servicing section of the manual for detailed instructions.

What to Check:

• Has product contaminated the poppet valve?

Correct Action:

• If a significant amount of product has made it into the poppet valve, then the unit will

need to be disassembled for inspection. Consult the AirVantage servicing section (p.23).

SEAL, O-RING

(Purchased Separately)

VALVE, POPPET

VALVE, SOLENOID

CAPSCREW, HEX SOC HD, 10-32 X .50

COVER

SEAL, O-RING

SEAL, O-RING

MUFFLER

SEAL, O-RING

ASSEMBLY, POWER GENERATOR

CAPSCREW, HEX SOC HD, 10-32 X 2.25

CAPSCREW, HEX SOC HD, 10-32 X 1.00

CAPSCREW, HEX SOC HD, 10-32 X .50

O-RING

O-RING

CONTROL MODULE

REGULATOR

Optional 1/4" NPT Pipe Plug (P/N 618.011.330)

Must be installed if performing direct spray

wash-down of pump