SANDPIPER RS30 Non-Metallic User Manual

Page 18

Advertising
background image

rs30nmdl2sm-rev0614

Model RS30 Non-Metallic Page 16

DUAL PORTING OPTIONS

Several dual porting options are

possible. The pump can be converted

to a dual port arrangement on both

the suction and the discharge ends.

The porting can be configured to a

single suction and a dual discharge.

The porting can be changed to a dual

suction and a single discharge.

The above changes are possible

because the porting flange of the

elbows (items 42) are designed to mate

with standard 125# ANSI style 4-bolt,

3" pipe flanges.

Dual porting of both suction and

discharge ends of the pump

Converting the pump from the

standard single suction and discharge

porting configuration to dual porting at

each end is easy. Simply remove the

manifold seals, spacers, and manifolds

(items 50, 40, and 61 from pump

assembly drawing) from the pump.

The discharge and suction elbows

can be rotated at 90° increments (see

arrows and optional positioning in the

Dual Porting Drawing.

Single porting of the suction and

dual porting of the pump discharge

To convert the pump from the

standard single suction and single

discharge porting configuration to a dual

discharge porting arrangement remove

the only the discharge manifolds,

spacers, and manifold seals. Position

the discharge elbows in the desired

direction at 90° increments. (See

arrows and optional positioning in the

Dual Porting Drawing.)

Dual porting of the suction and

single porting of the pump discharge

To convert the pump from the

standard single suction and single

discharge porting configuration to a dual

suction porting arrangement remove

the only the suction (bottom) manifolds,

spacers, and manifold seals.

Position the suction elbows in the

desired direction at 90° increments.

(See arrows and optional positioning

in the Dual Porting Drawing.)

Read these instructions

c om ple t e ly, be f or e

installation and start-

up. It is the responsibility

of the purchaser to

retain this manual for

reference. Failure to comply with the

recommendations stated in this manual

will damage the pump, and void factory

warranty.