Caution, Important, Warranty – SANDPIPER EB1/2-A User Manual

Page 4

Advertising
background image

Model EB½-A Type 2 Page 4

520-069-000 8/00

CAUTION

In the event of diaphragm rupture,
pumped material may enter the air end
of the pump, and be discharged into the
atmosphere. If pumping a product which
is hazardous or toxic, the air exhaust
must be piped to an appropriate area for
safe disposition.

CAUTION

Before maintenance or repair, shut off
the compressed air line, bleed the
pressure, and disconnect the air line
from the pump. The discharge line may
be pressurized and must be bled of its
pressure. When used for toxic or
aggressive fluids, the pump should
always be flushed clean prior to
disassembly.

IMPORTANT

This pump is pressurized internally with
air pressure during operation. Always
make certain that all bolting is in good
condition and that all of the correct
bolting is reinstalled during assembly.

further service instructions.

E. Blockage in the liquid chamber can impede movement of diaphragm.
2. Pump cycles but will not pump
A. Suction side of pump pulling in air. Check the suction line for air leaks and be sure

that the end of the suction line is submerged. Check flange bolting. Check valve
flanges and manifold to chamber flange joints.

B. Make certain the suction line or strainer is not plugged. Restriction at the suction

is indicated by a high vacuum reading when a vacuum gauge is installed in the
suction line.

C. Check valves may not be seating properly. To check, remove the suction line and

cover the suction port with your hand. If the unit does not pull a good suction
(vacuum), the check valves should be inspected for proper seating.

D. Static suction lift may be too high. Priming can be improved by elevating the

suction and discharge lines higher than the check valves and pouring liquid into
the unit through the suction inlet. When priming at high suction lifts or with long
suction lines operate the pump at maximum cycle rate.

3. Low performance
A. Capacity is reduced as the discharge pressure increases, as indicated on the

performance curve. Performance capability varies with available inlet air supply.
Check air pressure at the pump inlet when the pump is operating to make certain
that adequate air supply is maintained.

B. Check vacuum at the pump suction. Capacity is reduced as vacuum increases.

Reduced flow rate due to starved suction will be evident when cycle rate can be
varied without change in capacity. This condition will be more prevalent when
pumping viscous liquids. When pumping thick, heavy materials the suction line
must be kept as large in diameter and as short as possible, to keep suction loss
minimal.

C. Low flow rate and slow cycling rate indicate restricted flow through the discharge

line. Low flow rate and fast cycling rate indicate restriction in the suction line or air
leakage into suction.

D. Unstable cycling indicates improper check valve seating on one chamber. This

condition is confirmed when unstable cycling repeats consistently on alternate
exhausts. Cycling that is not consistently unstable may indicate partial exhaust
restriction due to freezing and thawing of exhaust air. Use of an anti-freeze lubri-
cant in an air line lubricator should solve this problem.

For additional information, see the Warren Rupp Troubleshooting Guide.

WARRANTY

This pump is warranted for a period of five years against defective material and

workmanship. Failure to comply with the recommendations stated in this manual
voids all factory warranty.

©2000 Warren Rupp, Inc. All rights reserved.

®Warren Rupp, SandPIPER, and Tranquilizer are registered tradenames of Warren Rupp, Inc.

®Neverseize is a registered tradename of Loctite

Printed in U.S.A.

RECOMMENDED WARREN RUPP ACCESSORIES
TO MAXIMIZE PUMP PERFORMANCE:

• Tranquilizer

®

Surge Suppressor. For nearly pulse-free flow.

• Warren Rupp Air Dryer. For clean, dry compressed air.

• WarrenRupp Filter/Regulator. For modular installation and

service convenience.

• Warren Rupp Speed Control. For manual or programmable

process control. Manual adjustment or 4-20mA reception.

For more detailed information on these accessories, contact your local
Warren Rupp Factory-Authorized Distributor, or Warren Rupp corporate
headquarters.

Advertising