ELECTRICAL REQUIREMENTS

OBSERVE ALL LOCAL CODES AND ORDI-

NANCES.

DO NOT, UNDER ANY CIRCUMSTANCES,
REMOVE THE POWER SUPPLY CORD

GROUND PRONG.

ELECTRICAL GROUND IS REQUIRED ON
THIS APPLIANCE


A 115-VOLT 60Hz, AC ONLY, 15A FUSED

AND PROPERLY GROUNDED ELECTRICAL

SUPPLY IS REQUIRED.

A time delay fuse or time delay circuit
breaker is recommended. Use a dedicated

circuit serving only
this appliance.


RECOMMENDED GROUNDING
METHOD

For your personal safety, this appliance
must be grounded. This appliance has a
power supply cord with a 3-prong

grounded plug. To minimize possible shock
hazard the cord must be plugged into a
matching grounded electrical outlet that

complies with the latest edition of the
National Electrical Codes and all local

codes and ordinances.

If a grounded 3-prong electrical outlet is

not available, it is the personal responsibil-
ity and obligation of the customer to have
one installed by a qualified electrician.

ELECTRICAL SHOCK HAZARD

Plug into a grounded 3-prong outlet.

Do not remove the ground pin from the

plug.

Do not use an adapter.

Do not use an extension cord.

Failure to follow these instructions can

result in death, fire or electrical shock.

3-prong grounded plug

Power supply cord

Grounded 3-prong
electrical outlet

INSTALLING YOUR DEHUMIDIFIER

Install the dehumidifier on a level floor

strong enough to support the unit with a
full bucket of water.

For best performance, allow at least 12-18

inches of air space on all sides of the unit
for good air circulation.

Keep all outside doors, windows and other

openings closed when operating the dehu-
midifier. Humid outdoor air will add to the

unit's workload.

Leave the dehumidifier in an upright posi-

tion for 30 minutes before turning on.


DEFROST OPERATION


The dehumidifier has a built-in defrost

control that senses frost buildup on the
evaporator coils.


During defrosting, the compressor will

automatically turn off; the fan will continue
running to defrost the coils.

WARNING

17

PRODUCT SPECIFICATIONS

EXTERNAL VERTICAL PUMP

Pump capacity per 24 hours

304 pints per day

Vertical Height Pumping

16 ft.

Power Source

115 V / 60 HZ

Rated Current (Amps)

.12A

Dehumidifier Drain Hose Diameter

.50 in. / 13 mm

Pump Drain Hose Inside Diameter

.20 in / 5 mm