OpERATINg YOUR FAN

IMpORTANT: dO NOT OpERATE ThE FAN WIThOUT FIRST

OpENINg A WINdOW OR dOOR TO pROvIdE INLET AIR FLOW. IF

FAN IS LOCATEd IN hALL, YOU MUST OpEN dOORS TO hALL TO

ALLOW AIR FLOW INTO ThE FAN.

The air movement in rooms can be increased by closing off parts of

the house. Each room must be treated as a separate ventilating case.

Always open the window farthest from the point that the air will leave

the room.

For best cooling results from your WHOLE HOUSE FAN open only

the windows in the room being use.

IMpORTANT: Fan should always be started on hIgh SpEEd to

prevent possible motor failure.

120V

60 Hz

Power

Supply

Motor

BLACK

(high speed)

BLACK

(line)

GREEN

GREEN

RED

(low speed)

WHITE

(common)

FIg. 5

FIg. 6

FIg. 7

Key Part

Part

No. Number

Description

1

WPCA24FRA

24" Fan Frame (Venturi)

WPCA30FRA

30" Fan Frame (Venturi)

2 PP

1

4

HP Motor

3

WPCA24BA

24" Fan Blade

WPCA30BA

30" Fan Blade

4

PP1032 NUT

Nut (4 req’d - #10 - 32)

5

PP

3

16

WSH

Washer (4 req’d -

3

16

Flat)

6

PPRUBMOT

Grommet (8 req’d)

7

PPCA24SKT

24" Fan Skirt

PPCA30SKT

30" Fan Skirt

8

PP10X.75

Screw (12 req’d - #10 x

3

4

)

9

PPFENDER

Washer (16 req’d -

3

16

Fender)

10

PPHANDYC

Cover, Switch Box

11

PPPULLSW

Switch, 2-Speed

12

PPSTRAIN

Strain Relief

FGCSS24

Shutter - 24" Fan

FGCSS30

Shutter - 30" Fan

†* FG2SPWALL

2-Speed Wall Switch

†* FG12HRTIM

12-Hour Timer

†* FG2SP12HR

2-Speed, 12 hr. Timer Wall Switch

† Not Illustrated †* Optional

Specifications subject to change without notice.

REPAIR AND REPLACEMENT PARTS

STEp 4.

- TURN OFF pOWER AT FUSE bOX OR CIRCUIT

bREAkER.

The fan requires a 120 volt A.C. power source with

at least 5 amp capacity. All electrical work must be in accordance

with local building codes using approved material. Follow wiring

diagram as shown below in FIg. 5 to finish electrical installa-

tion. Before restoring power, be certain the fan blades are clear

as the pull chain switch may be in the “on” position. If you are

using a separately purchased wall mounted control, follow

the instructions furnished with that control.

STEp 5.

Cut out the plenum at premarked openings to fit your

ceiling joists. Attach the plenum to the deck using the #10 screws

and fender washers provided . Staple or tack the plenum to the

ceiling joist. Improper installation of the plenum can result in poor

fan performance or possible motor failure. Re-install insulation to

the edge of the plenum. Cover any opening with duct tape. The

plenum must be tightly sealed to the fan, joists and ceiling so the

fan draws air from the living area only. (FIg. 6)

STEp 6.

Install flush mounted ceiling shutter into the ceiling

opening using the #10

1

4

" screws included in the shutter carton.

Caution should be taken not to effect the free operating action

of the shutter. Drop the pull chain through the hole provided in

the shutter and trim it to desired length. Your installation is now

complete. (FIg. 7)