3 chuck control connections, Huck, Ontrol – Walker Magnetics SMART-D SERIES User Manual

Page 24: Onnections, Able, Erminal, Tb1 -3, Onnector, J4 -3, J5 -3

Advertising
background image

O.S. WALKER Co., Inc. SMART-D Control

SMART D MANUAL DD14511L Rev. L, March 30, 2011

5-3

5.3 Chuck Control Connections

Table 5-1 Terminal TB1

1 (+) Chuck

DC

2 (-) Chuck

DC

Table 5-2 Connector - J4

1,2

Lockout Supply Relay Contacts

3,4,5

Part Released Signal Relay Contacts

6,7,8

Current Sense Relay Contacts

Table 5-3 Connector - J5

1

50K Ohm Variable Potentiometer

2 GND

3

Release Lamp

4

Variable Lamp

5 Full

Lamp

6 Residual

Lamp

7 LED

Common

8 Lockout

Option

9 Variable

Pushbutton

10 Full

Pushbutton

11 Residual

Pushbutton

12 Release

Pushbutton

13

GND (Pushbutton Common)

14 +5V

15

# of Release Pulses

16 Lamp

Common

Adjustments

Number of Release Pulses (1-16) - Set to 8 pulses at factory (See Release section 4.5 page
4-3
)

Advertising