HUB-40Ex Sensor

User Manual

AW Gear Meters

8809 Industrial Drive, Franksville, WI 53126

 web: www.awgearmeters.com

 Tel: 262-884-9800

 Fax: 262-884-9810

 Email: [email protected]

HUB-40Ex User Manual rev1.2.docxError! Unknown document property name., 1/18/2012

PAGE: 2 of 4

HUB-40Ex USER MANUAL

Introduction/ Features:

The HUB-40Ex is a frequency output, pickup sensor certified for use in explosion proof areas. The sensor detects the
rotation of an approved

flow meter’s gears and emits a frequency signal proportional to the flow. The output signal is a

square wave pulse, which has a duty cycle of approximately 50%. MAG signal outputs are protected with a self-resetting
fuse. This fuse has a 50 mA nominal trip point. When a trip occurs, turn off power to the sensor and remove output load to
reset the fuse.

Compatible flow meters include:

JVM-zzz-Ex Models

JVS-zzz-Ex Models

JVHS-zzz-Ex Models

ZHM-zzz-Ex Models

HPM-zzz-Ex Models

HM-zzz-AC-Ex Models

Specifications:

Supply Voltage: 10 to 24 VDC

Supply Current:

o 8 mA @ 12 VDC
o 12 mA @ 24 VDC
o 65 mA MAXIMUM

Sensor/Monitor Frequency Output: Flow dependent,
0.5 Hz minimum

Output Amplitude:

o V

HIGH

= V

SUPPLY

– 0.7 Volts

o V

LOW

= 0 Volts

Duty Signal: 50% + 15%

Connections

: terminal block, ½” NPT (FEMALE)

conduit entrance.

Temperature Ratings:

o -20°C to +60°C (-4°F to +140°F) ambient
o 85°C (185°F) maximum fluid temperature

HUB-40Ex Certifications:

o CSA

 CL. I, DIV. 1, GR. C,D
 CL. II, DIV. 1, GR. E,F,G
 CL. III

Enclosure Certifications: TYPE 4X

HUB-40Ex Dimensions:

Advertising