Installation:

Ensure that the sensor cavity of the flow meter is free of debris prior to installation.

Mount the HUB-40Ex into the sensor cavity and fasten threads. NOTE: REFER TO SECTION TITLED

Special

installation instruction for use in Hazardous Area environments

FOR PROPER INSTALLATION

REQUIREMENTS!

Slightly loosen Swivel Union nut and adjust the junction box in the desired orientation.

Tighten the Swivel Union nut while maintaining the orientation of the junction box. To properly seal surfaces from
external environment, apply 65 ft-lbs (+/- 4 ft-lbs) of torque. It is recommended to use anti-seize grease on threads to
avoid galling.

Remove conduit plug from the junction box to allow wire access, and remove the junction box lid to allow access to
terminal block connections.

Connect the wires to the appropriate terminals shown in the wiring guide.

Reapply the junction box lid until fully engaged and fasten setscrew.

Seal off conduit connection. NOTE: REFER TO SECTION TITLED

Special installation instruction for use in

Hazardous Area environments

FOR PROPER INSTALLATION REQUIREMENTS!

Wiring Guide: