2. Adjust flash rate. Beacons are factory defaulted to mode

"Flash 3" (65 flashes per minute).

a. Remove globe section; loosen the globe and ring

assembly set screw. Insert a suitable tool into the

notches in the globe and ring assembly and loosen the

assembly by prying in a counterclockwise direction.

Remove the ring and globe assembly.

b. Set dipswitch (Figure 7) for desired flash rate. Refer

to Table 3 for dipswitch settings.

c. To replace, simply screw the globe assembly unit

on until it seats firmly onto its gasket. Tighten the unit

another 1/8 to 1/4 turn. Tighten the set-screw.

WARNING

To reduce the risk of ignition of hazardous

atmospheres and shock, keep assembly tightly

closed when circuits are energized.

To reduce the risk of ignition of hazardous

atmospheres and shock, disconnect from the

supply and circuit and allow five (5) minutes for

stored energy to dissipate before disassembling

the unit.

Disassemble the unit as follows (Figure 8):

1. Loosen the (3) guard screws and remove the guard.

2. Loosen the globe and ring assembly set screw. Insert a

suitable tool into the notches in the globe and ring assembly

and loosen the assembly by prying in a counterclockwise

direction. Remove the ring and globe assembly.

3. Refer to Table 1 for the correct replacement catalog number

and replace the necessary part.

4. To replace, simply screw the unit on until it seats firmly onto

its gasket. Tighten the unit another 1/8 to 1/4 turn. Tighten

the setscrew.

5. Reinstall the guard, where applicable, and secure using the

three supplied screws.

6. After the unit is assembled, apply power and make sure the

unit functions properly.

WARNING

To reduce the risk of ignition of hazardous

atmospheres and shock, keep assembly tightly

closed when circuits are energized.

3. Apply power to the unit and ensure proper function.