MULTI-OUTPUT POWER SUPPLY

USER MANUAL

2

2. SPECIFICATIONS

2-1. General

Main Supply (switch selectable)

: 100V/120V/220V ± 10%(230V +10%~-6%) 50/60Hz.

Operation Environment

:Indoor use.

Altitude up to 2000m.
Ambient temperature 0℃ to 40℃.
Relative humidity 80% (maximum).
Installation category II.
Pollution degree 2.

Storage Temperature & Humidity

: -10℃ to 70℃.70% (maximum).

Accessories

: Operation Manual ×1.

Table 2-1:

REPLACED FUSE TYPE RATES INPUT

TEST LEAD

MODEL

Independent Series Para

100V/120V 220V/230V

WATTS

VA

Current

≦3A

4A≦

Current<10A

GPS-2303

0~30V×2
0~3A×2

60V
3A

30V
6A

T6A
250V

T3A 250V

350

450

0

2

GPS-3303

0~30V×2
0~3A×2

60V
3A

30V
6A

T6.3A
250V

T3.15A 250V

420

550

1

2

GPS-4303

0~30V×2
0~3A×2

60V
3A

30V
6A

T6.3A
250V

T3.15A 250V

420

550

2

2

GPS-4302

0~30V×2
0~2A×2

60V
2A

30V
4A

T5A
250V

T3A 250V

320

420

2

2

GPS-4251

0~25V×2
0~0.5A×2

50V
0.5A

25V
1A

T2.5A
250V

T1.25A 250V

150

185

4

0

Dimensions :

255(W)

×145(H) ×265(D) m/m

Weight (kg)

: 7.0 kg.

2-2. Operation

Mode

(1) Independent

: Two independent outputs and
CH3: 2.2~5.2V output for GPS-4302/4303, 3~6V

output for GPS-4251, Fixed 5V for GPS-3303.

CH4: 8~15V output for GPS-4302/4303/4251.

Output from 0 to rating volts and 0 to rating amperes.

(2) Series

: Output from 0 to rating volts at rating amperes each.
: Output from 0 to double rating volts at rating amperes.

(3) Parallel

: Output from 0 to double rating amperes at rating

volts.

2-3. Constant Voltage Operation

(1) Output voltage range

: 0 to rating voltage continuously adjustable.

(2) Regulation

: Line regulation≦0.01% + 3mV.
: Load regulation≦0.01%+3mV(rating current≦3A).
: Load regulation≦0.02%+5mV ( rating current>3A).

MULTI-OUTPUT POWER SUPPLY

USER MANUAL

3

(3) Recovery time

:≦100μs (50% load

change, minimum load 0.5A ).

(4) Ripple & Noise

:≦1mVrms (5Hz-1MHz ).

(5) Temperature coefficient

:≦300ppm/℃.

2-4. Constant Current Operation

(1) Output current range

: 0 to rating current continuously adjustable.

(2) Regulation

: Line regulation≦0.2% + 3mA.
: Load regulation≦0.2% +3mA.

(3) Ripple current

:≦3mArms.

2-5. Tracing

Operation

(1) Parallel Operation

Regulation

: Line regulation≦0.01% + 3mV.
: Load regulation≦0.01%+3mV (rating current≦3A).

≦0.02%+5mV (rating current >3A).

(2) Series Operation

Regulation

: Line regulation≦0.01%+5mV.
: Load regulation≦300mV.

A. Positive and Negative supply (Fig 5-4) CH2 tracking error ≦0.5%+10mV of the CH1

(No load, with load add load regulation≦300mV)

B. Single supply (Fig. 5-3)

2-6. Meter

A. Display A

: 3 digits panel meter×2 (0.5” Red LED display).

Display V

: 3 digits panel meter × 2 (0.5” Green LED display).

B. Accuracy

:OUT ON±(0.5% of rdg + 2 digits)
:OUT OFF±(0.5%

of rdg+8 digits)

(When the output of

the GPS-2303 is set to OFF, its voltage meter and
current meter can not preview)

C. Voltmeter

: 99.9V of full scale.

D. Ammeter

: 9.99A of full scale.

2-7. CH3 Output Specifications

(1) Regulation

: Line regulation≦5mV, load regulation≦15mV.

(2) Ripple & Noise

: ≦2mVrms.

(3) Outout Voltage range

: GPS-4302/4303: 2.2~5.2V±8% continuous adjustment,

GPS-3303 fixed 5V±8% continuous adjustment,
GPS-4251 3~6V±8% continuous adjustment

(4) Output current

: 3A for GPS-3303&4302, 1A for GPS-4303, 2.5A for

GPS-4251.

2-8. CH4 Output Specifications

(1) Regulation

: Line regulation≦5mV, load regulation≦10mV.

(2) Ripple & Noise

:≦2mVrms.

(3) Outout Voltage range

: GPS-4302/4303/4251: 8~15V±8% continuous

adjustment.

Advertising