HT instruments HT14N User Manual

Page 10

Advertising
background image

HT-14N

EN - 9

5. TECHNICAL SPECIFICATIONS

5.1. CHARACTERISTICS

Accuracy is indicated as

± [% of reading].

It is referred to the following reference conditions: 23°C ± 5°C with RH <75%.

5.1.1. DC Voltage

Range Sensitivity

Accuracy

2.5V

2k

Ω/V

± (5% of full scale)

25V

2k

Ω/V

± (5% of full scale)

250V

2k

Ω/V

± (5% of full scale)

500V

2k

Ω/V

± (5% of full scale)

Meter resistance: 2k

Ω/V


5.1.2. AC Voltage

Range Sensitivity

Accuracy

25V

2k

Ω/V

± (5% of full scale)

250V

2k

Ω/V

± (5% of full scale)

500V

2k

Ω/V

± (5% of full scale)

Meter resistance: 2k

Ω/V


5.1.3. AC Current

Range Accuracy

1mA

± (5% of full scale)

10mA

± (5% of full scale)

100mA

± (5% of full scale)


5.1.4. Resistance

Range Accuracy

R x 10

± (5% of full scale)

R x 100

± (5% of full scale)

R x 1K

± (5% of full scale)

5.1.5. Battery Test

Range Test

current

Accuracy

1.5V 100mA

± (10% of full scale)

9.0V 10mA

± (10% of full scale)


Advertising