HT instruments HT14N User Manual

Page 11

Advertising
background image

HT-14N

EN - 10

5.1.6. Safety
Comply with:

EN 61010-1.

Insulation:

Class 2, double reinforced insulation.

Pollution: Level

2.

For inside use, max height:

2000m.

Over voltage:

CAT II 300V.

5.1.7. General data
Mechanical characteristics
Size:

80 (W) x 145(H) x 45(D)mm.

Weight (including battery, holster and test leads): about 250g.

Supply
Battery type:

UM3 single 1.5Volt AA size battery, IEC
LR6.

Battery life (only for

Ω measurement):

About 10 hours of continuos work.

Fuse:

5 x 20mm 500mA/250V Fast Acting.


Display
Display Type:

Analog display.



5.2. ENVIRONMENTAL CONDITIONS

5.2.1. Climatic conditions
Reference temperature:

23 ± 1°C

Operating and storage temperature:

5 ÷ 40°C

Operating and storage humidity: <75%

RH


This product conforms to the prescriptions of the European directive on low voltage

2006/95/EEC (LVD) and to EMC directive 2004/108/EEC


5.3. ACCESSORIES

5.3.1. Standard accessories
The accessories contained inside the packaging are the following:
• Instrument.

• Test

leads.

• Instruction

manual.

• Holster.

• Battery.

Advertising