HT instruments HT4012 User Manual

Page 42

Advertising
background image

HT4012

EN - 17

6.1.1. Safety
Comply with:

EN 61010

Insulation:

Class 2, double reinforced insulation

Pollution: Level

2

For inside use, max height:

2000m

Over voltage:

CAT III 600V (between ground and input terminal)

6.1.2. General

data

Mechanical characteristics
Size:

205(L) x 64 (W) x 39(H)mm; 8.04 x 2.52 x 1.54 in

Weight (including battery):

About 280g; 9.88 ounce

Jaws opening:

30mm; 1.18 in

Max conductor size:

30mm; 1.18 in


Supply
Batteries type:

2 batteries 1.5V LR03 AAA.

Low battery indication:

Symbol "

" is displayed when battery level is

too low

Battery life:

About 100 hours


Display
Characteristics:

3 ½ LCD with maximum reading 1999 units plus
decimal point signs.

Sample rate:

2 times/sec.

Conversion mode:

Mean value


6.2. ENVIRONMENTAL CONDITIONS

6.2.1. Climatic

conditions

Reference temperature:

23° ± 5° C; 73° ± 41°F

Operating temperature:

5° ÷ 40° C; 41° ÷ 104°F

Operating humidity:

<80% RH

Storage temperature:

-10° ÷ 60° C; 14° ÷ 140°F

Storage humidity:

<80% RH


6.2.2. EMC and LVD
This apparatus was designed in accordance with EMC standards in force and its
compatibility has been tested in accordance EN61326 (1997) + A1 (1998) + A2 (2001).

This product conforms to the prescriptions of the European directive on low voltage
2006/95/EEC (LVD) and to EMC directive 2004/108/EEC

6.3. ACCESSORIES

6.3.1. Standard

accessories

The accessories contained inside the packaging are the following:

• Instrument

HT4012.

• Couple of test leads.

• Rubber test lead holster.

• User’s

manual.

• Carrying

bag.

• Batteries.


6.3.2. Optional

accessories

• 4413-2: couple of 4mm test leads.

Advertising