HT instruments HT9 User Manual

Page 15

Advertising
background image

HT6-HT8-HT9

EN - 14

7.2. GENERAL

CHARACTERISTICS

Power supply
Internal power supply:

2x1.5V AAA, IEC LR03

Mechanical characteristics
Size:

255(L) x 60(La) x 35(H)mm

Weight (battery included):

approx. 170g

Mechanical protection:

IP64

Considered standards
Instrument safety:

IEC/EN61010-1 (HT8, HT9);

IEC/EN61010-2-030 (HT8, HT9);

IEC/EN61243-3:2010 (HT6, HT8, HT9)

Insulation: double

insulation

Overvoltage category:

CAT III 690V; CAT IV 600V

Max height:

2000m

Pollution level:

2

7.3. ENVIRONMENT
7.3.1. Environmental conditions for use
Calibration reference temperature:

23 ± 5°C

Operating temperature:

-15 ÷ 55°C

Allowable relative humidity:

<85%

Storage temperature:

-20 ÷ 70°C


This instrument satisfies the requirements of Low Voltage Directive 2006/95/EEC

(LVD) and of EMC Directive 2004/108/EEC


7.4. ACCESSORIES
7.4.1. Accessories

provided

 Batteries (not inserted)

 User

manual

 Protective cap for test leads, 2 pcs

 Adapter for 4mm test lead tip, 2 pcs

Advertising
This manual is related to the following products:

HT8, HT6