1. SAFETY PRECAUTIONS AND PROCEDURES

This instrument complies with EN 61010-1 concerning electronic measuring instruments.
For your own safety and to avoid damaging the instrument follow the procedures
described in this instruction manual and read carefully all notes preceded by this symbol

.


When taking measurements:

• avoid doing that in humid or wet places - make sure that humidity is within the limits

indicated in section “environmental conditions”.

• avoid doing that in presence of explosive gas, combustible gas, steam or excessive

dust.

• do not touch exposed metal (conductive) parts such as test lead ends, sockets, fixing

objects, circuits etc.

• avoid doing that if you notice anomalous conditions such as breakages, deformations,

fractures, foreign substances, blind display etc.

• avoid measuring higher voltages than 20V as you may risk electrical shocks.

The following symbols are used:

Caution: refer to the instruction manual; an improper use may damage the
instrument or its components

Danger high voltage: risk of electrical shocks

Double insulated meter

AC voltage

DC voltage

DC/AC voltage


1.1. PRELIMINARY
• This instrument has been designed for use in environments of pollution degree 2.

• It can be used for VOLTAGE measurements on installations of CATIV 600V.

• Only the original test leads supplied along with the instrument guarantee compliance

with the safety standards in force. They must be in a good conditions and, if necessary,
replaced with identical ones.

• Do not test nor connect to any circuit exceeding the specified overload protection.

• Do not take measurements under environmental conditions exceeding the limits

indicated in chapter 6.2.1.

• Make sure that batteries are correctly installed.

• Before connecting the test probes to the installation make sure that the rotary selector

is positioned on the right function.

• Make sure that LCD and rotary selector indicate the same function.