HT instruments HT9021 User Manual

Page 20

Advertising
background image

HT9021

EN - 19

Supply
Battery type:

1 battery 9V NEDA 1604 IEC 6F22 JIS 006P.

Low battery indication:

” is displayed when the battery level is low

Battery life:

about 200 hours

AutoPowerOff:

after 15 minutes of idleness

Display
Characteristics:

4 LCD (max 6000 counts), decimal point, unit symbol
indication, bargraph and backlight

Sample rate:

2 times/sec

Conversion mode:

TRMS


6.2. ENVIRONMENTAL CONDITIONS
6.2.1. Climatic conditions
Reference temperature:

18°C

÷ 28°C (65°F ÷ 83°F)

Operating temperature:

0 ÷ 40 °C (32°F

÷ 104°F)

Operating humidity:

< 75%RH

Storage temperature:

-20 ÷ 60 °C (-4°F

÷ 140°F)

Storage humidity:

< 80% RH


This product conforms to the prescriptions of the European directive on low voltage

2006/95/EEC and to EMC directive 2004/108/EEC


6.3. STANDARD ACCESSORIES
• Test leads – Code 4413-2

• Adapter + type K bead probe

• Carrying

bag

• User

manual

• Battery

6.4. OPTIONAL ACCESSORIES
The herewith type K probes are avaliable:

Model Description

Temperature

range

Accuracy

(at 100°C)

Probe length

(mm)

Probe diameter

(mm)

TK107

Air and gas
temperature

-40

÷ 800 °C

± 2.2rdg

200

1.5

TK108

Inner temperature of
semisolid
substances

-40

÷ 800 °C

± 2.2rdg

200 3

TK109

Inner temperature of
fluids

-40

÷ 800 °C

± 2.2rdg

200 4

TK110

Surface temperature -40

÷ 400 °C

± 2.2rdg

200 5

TK111

Surface temperature
with fixed tip at 90°

-40

÷ 400 °C

± 2.2rdg

260 5



Advertising