1 selecting bipolar/independent protection limits, Voltage and current parameter definitions -13, R. 3.3.3.1) – KEPCO BOP 1KW-MG Operator Manual, Firmware Ver.2.38 to 2.47 User Manual

Page 77

Advertising
background image

BOP HIPWR 080709

3-13

3.3.3.1

SELECTING BIPOLAR/INDEPENDENT PROTECTION LIMITS

The BOP can be configured to show the protection limits as either a single value that applies to
both protection channels or show individual settings for positive and negative protection limits.
Selecting Independent protection limits means that the positive and negative limits are dis-
played (and can be modified) independently. Bipolar means that for each protection limit (volt-
age or current) a single value applies to both the positive and negative limits; only one value is
displayed and can be edited for both ± protection limits.

TABLE 3-4. VOLTAGE AND CURRENT PARAMETER DEFINITIONS

Term

Definition

To modify

refer to PAR.

Local

Remote

+E

Onom

–E

Onom

The nominal (rated) output voltage of the unit determined by model; e.g. for
a BOP 36-28MG, ±E

Onom

is 36V.

N/A

N/A

+I

Onom

–I

Onom

The nominal (rated) output current of the unit determined by model; e.g. for
a BOP 36-28MG, ±I

Onom

is 28A.

N/A

N/A

+Voltage
–Voltage

Voltage mode only. Positive (+) and negative (–) output voltage values
established by keypad or remote command.
Range (+): 0 to +Voltage max
Range (–): 0 to –Voltage min

3.3.3

B.84

+Voltage max
–Voltage min

Voltage mode only. Maximum (positive) and minimum (maximum negative)
voltage that can be set.
Value (+): 0 to +E

Onom

Value (–): 0 to –E

Onom

3.3.4.1

B.86, B.87,

B.88, B.90

+Current Protect
–Current Protect

Voltage mode only. Defines maximum (+) current and Minimum (maximum
negative) (–) that unit can source or sink.
Range (+): +Current Protect min to +Current Protect max
Range (–): –Current Protect max to –Current Protect min

3.3.3

B.27, B.28,

B.33, B.31

+Current Protect Max
–Current Protect Min

Voltage mode only. Maximum setting for +Current Protect and Minimum
(maximum negative) setting for –Current Protect.
Value (+): +Current Protect min to (1.01 x +Current max)
Value (–): –Current Protect max to (1.01 x –Current min)

3.3.4.2

B.35, B.36,

B.39, B.37

Minimum (box)
+Current Protect Min
–Current Protect Max

Voltage mode only. Minimum (positive) setting for +Current Protect and
maximum (maximum negative) setting for –Current Protect. Values of ±Cur-
rent Protect between +Current Protect Min and –Current Protect Max (near
zero) are not allowed.This zone (also referred to as the minimum (box) is
automatically calculated by the BOP (see Figure 1-3).

N/A

N/A

+Voltage Protect
–Voltage Protect

Current mode only. Maximum positive (+) and minimum (maximum
negative) (–) voltage that can appear at the output.
Range (+): +Voltage Protect min to +Voltage Protect max
Range (–): –Voltage Protect max to –Voltage Protect min

3.3.3

B.94, B.95,

B.100,

B.98

+Voltage Protect Max
–Voltage Protect Min

Current mode only. Maximum (positive) setting for +Voltage Protect and
Minimum (maximum negative) setting for –Voltage Protect.
Value (+): +Voltage Protect min to (1.01 x +Voltage max)
Value (–): –Voltage Protect max to (1.01 x –Voltage min)

3.3.4.2

B.102,
B.103,
B.106,

B.104