1-3

OUTPUT CHARACTERISTICS (Continued)

Readback
rate/array

measurement rate

5 ms (default)

range (voltage or current): 500

µ

sec to 500ms

range (voltage + current): 1msec to 250ms

measurement array

64 samples

Voltage

128 samples

Current

Voltage stabilization in
voltage mode

source effect

0.05% of rating

min-max input voltage

load effect

0.1% of rating

0-100% load current

time effect (drift)

0.02 of rating

0.5 through 8 hours

temperature effect

0.02%/deg C of rating

0 to 50 deg C

ripple and noise

2% E0max p-p

Includes switching noise

Current stabilization in
current mode

source effect

0.05% of rating

min-max input voltage

load effect

0.2% of rating

0-100% load voltage

time effect (drift)

0.02% of rating

0.5 through 8 hours

temperature effect

0.02%/deg C of rating

0 to 50 deg C

ripple and noise

2% I0max p-p

Includes switching noise

Error sensing

0.25V per wire

Above rated output

Transient recovery in volt-
age mode

maximum excursion

5% of nominal output

nominal voltage, 50% load step

Recovery time

200

µ

sec

Return within 0.1% of set voltage

Isolation

voltage

300V

Output to ground

Series operation

Master/slave

Maximum of identical 3 units,
up to 300V max.

Parallel operation

Master/slave

Maximum of 5 identical units

Series-parallel Operation

2 series x 2 parallel
3 series x 2 parallel

Master/slave for both series and parallel
branches of identical units

Output Protection limiting

voltage and current limited in four quadrants, adjustable between ±Internal minimum

EO

MIN

or IO

MIN

(box) (see Figure 1-2) and ±1.01 EO

NOM

or IO

NOM

.

Output Stage Protection

Output overvoltage/overcurrent

Heatsink overtemperature,

switchers overcurrent

Triggers latched shutdown protection of the
output module and PFC stage. Recover by
cycling power off, then on or by pressing
RESET at the front panel.

Input Stage Protection (PFC)

Internal overvoltage, undervoltage,

overcurrent, heat sink

overtemperature, fan inoperative

Input circuit breaker overcurrent

Trips circuit breaker to shut off unit

Small signal
Bandwidth

voltage channel

2 KHz minimum

Into nominal resistive load 10% of rating

current channel

800 Hz minimum

Into short circuit, 10% of rating

Rise/Fall time

voltage channel

250/200

µ

Sec

Into nominal resistive load, measured from 10
to 90%, from 0 to ±100% of rating

current channel

0.7/1.2 mSec

Into short circuit, measured from 10 to 90%,
from 0 to ±100% of rating

TABLE 1-2. BOP GENERAL SPECIFICATIONS (Continued)

SPECIFICATION

RATING/DESCRIPTION

CONDITION