Table 3-14. revisions/test menu, 1 fixed gain using external reference control, Fixed gain using external reference control -37 – KEPCO BOP 1KW-MG Operator Manual, Firmware Ver.2.01 to 2.37 User Manual

Page 97: 14 revisions/test menu -37, R. 3.4.3.1, Le 3-14), R. 3.4.3.1 for

Advertising
background image

BOP HIPWR 022108

3-37

3.4.3.1

FIXED GAIN USING EXTERNAL REFERENCE CONTROL

The main channel of the BOP, voltage in voltage mode, and current in current mode, can be
controlled by an external reference voltage, 0 to ±10V applied at pin 11, referenced to pin 4, of
the Analog I/O port. The input impedance for this signal is 20K ohms. This feature is enabled as
follows:

1. From the power-up screen, press

$

, highlight Reference Input and press

!

. Highlight

External and press

$

to save. Then press

%

to apply the changes (without saving for

power-up) and exit. NOTE: This setting can be saved for power-up only by using the pass-
word-protected Power-up Settings menu (see {PAR. 3.3.7), otherwise internal references
are used for both main and protection channels upon power-up.

2. To return to digital or local control, from the power-up screen press

$

, then highlight Refer-

ence Input and press

!

. Highlight Internal and press

$

to save. Then press

%

to apply

the change and exit.

TABLE 3-14. REVISIONS/TEST MENU

SETTING

CHOICES

(BOLD = Factory Default)

FUNCTION

MAXIMUM OUTPUT

VOLTAGE XX

CURRENT YY

(Cannot be highlighted)

XX.0

YY.0

Displays rated output voltage and current of power supply. including all slaves
connected in parallel or series.

TEST

DISPLAY

Status (see NOTE below)

Automatic test, reports status messages (see NOTE below).

KEYPAD

Status (see NOTE below)

Requires depressing keys indicated on LCD.
This test requires pressing every key on the keypad, plus moving the
ADJUST control clockwise and counterclockwise, with the ADJUST control
depressed and released. As the keys and control function pass the tests, the
corresponding function on the LCD is highlighted. When the last test is suc-
cessful, the LCD displays “passed.” The test must be completed within two
minutes, otherwise a “Failed” indication is displayed.

INTER-

FACE

Status (see NOTE below)

Automatic test, reports status messages (see NOTE below).

SERIAL

Status (see NOTE below)

Automatic test of serial port - requires installation of loop back test connector.
(see PAR. 3.5.6.4). Reports status messages (see NOTE below).

ANALOG

Status (see NOTE below)

Automatic test which does not affect unit output. Reports status messages
(see NOTE below).

OUTPUT

Status (see NOTE below)

CAUTION: DISCONNECT LOAD BEFORE RUNNING THIS TEST. Output
is automatically programmed to +

E

Onom

for ~800 msec, then –

E

Onom

for

~800 msec, then to 0V. Reports status messages (see NOTE below).

REVISIONS

DISPLAY

INTERFACE

ANALOG

(Cannot be highlighted)

x.xx
y.yy
z.zz

Displays current firmware revision for display, interface and analog proces-
sors.

NOTE: Test status is as follows:

UNTESTED

Initial status when first entering menu.

TESTING

Test is running.

PASSED

Test was successful.

FAILED

Test failed.

FAIL EXT

SERIAL test failed - verify loop back connector installed (see PAR. 3.5.6.4).