3-10

SERIES EL 070312

FIGURE 3-2. MASTER/SLAVE START-UP, COMPUTER DISPLAY (SHEET 2 OF 2)

KEPCO, EL 5K-600-200 03-15-2010,A104503,MCB #234 1.219 $ 2010/03/26 12:58:08 $

Chassis Serial Number: A104503

Voltage range : 800V

Current range : 200.0

System damping : 5

PFM damping : 3

Overvoltage limit : 799.0

Undrvoltage limit : 0.000

Overcurrent limit : 600.0

Overpower limit : 6.000

System mode (startup): CURRent

System mode (now) : CURRent

Setpoints

Voltage : 660.0

Current : 0.000

Power : 0.000

Resistance : 1000.

Conductance : 0.001

IP Mode : Static

IP Address : 0.0.0.0

Sub Net : 0.0.0.0

Gateway : 0.0.0.0

DNS Addr : 0.0.0.0

Querying Power FET Module 0 [FET Board # 257 in position 0< 0>]

Found Ser# 257 at position 0 of 1

Querying Power FET Module 1 [FET Board # 258 in position 1< 0>]

Found Ser# 258 at position 1 of 2

Querying Power FET Module 2 [FET Board # 259 in position 2< 0>]

Found Ser# 259 at position 2 of 3

Querying Power FET Module 3 [FET Board # 260 in position 3< 0>]

Found Ser# 260 at position 3 of 4

Querying Power FET Module 4 [FET Board # 261 in position 4< 0>]

Found Ser# 261 at position 4 of 5

Querying Power FET Module 5 [FET Board # 262 in position 5< 0>]

Found Ser# 262 at position 5 of 6

Querying Power FET Module 6

Querying Power FET Module 6

Querying Power FET Module 6 ZYX

Discover Slaves

9

Setting serial # 222 as slave #0

8

Setting serial # 223 as slave #1

7654321

N MCB-Serial Amps Volts Kwatts Ilast Eng Md Setpt Iover Vover Vundr Pover

Master 630 660 15 0 0 2 0 600000 799000 0 6000000

0 222 210 660 5 0 0 0 0 0 0 0 0

1 223 210 660 5 0 0 0 0 0 0 0 0

46

###

Current EL Load

User Settings

Note: This same

information can be

displayed at any time

by entering the SCPI

command:

SYST:SETTING?

User protection

settings (values

shown are for no

user protection).

User operating

parameter settings

(values shown are for

no current draw at

turn on). Note: Each

parameter is retained

by Mode and is

stored in non-volatile

memory.

Load Dialog During

Process of

recognizing Power

FET Modules found

By Master Control

Board.

Testing for additional Power FET Modules and seeking possible

connections to slave Loads.

Discovering Slave Loads

found by Master Load

Master Control

Board Serial Nos.

Master boot

time (Seconds)

Load System Current

Voltage and Power Limits

Load System overcurrent,

overvoltage, under voltage,

overpower Limits

(mA, mV, mV, mW)