3 scpi subsystem command/query structure, 1 diagnostic subsystem, Table 3-2. remote operation command summary – KEPCO EL Series Electronic Load Operator Manual P/N 243-1295 Firmware Version 3.63 through 3.86 User Manual

Page 47: Scpi subsystem command/query structure -11, Diagnostic subsystem -11, Remote operation command summary -11

Advertising
background image

SERIES EL 070312

3-11

3.13.3

SCPI SUBSYSTEM COMMAND/QUERY STRUCTURE

Subsystem commands/queries are related to specific electronic load functions (such as setting
voltage, current limit, etc.) Figure 3-3 is a tree diagram illustrating the structure of SCPI subsys-
tem commands used in the EL Series Electronic Load with the “root” at the left side, and specific
commands forming the branches. The following paragraphs introduce the subsystems; subsys-
tem commands are defined and explained in Appendix B.

3.13.3.1 DIAGNOSTIC SUBSYSTEM

This subsystem is used to print the SCPI command set.

TABLE 3-2. REMOTE OPERATION COMMAND SUMMARY

Command

Function

CONTROL COMMANDS. Terminate command with ? to display established mode.

MODE CURRent

Enter Constant Current mode

MODE VOLTage

Enter Constant Voltage mode

MODE POWer

Enter Constant Power mode

MODE RESistance

Enter Constant Resistance mode

MODE CONDuctance

Enter Constant Conductance mode

MODE SHORt

Enter Short mode

MODE OFF

Disengage load and enable viewing of Model data.

INPut 1 or INPut ON

(alternatively OUT 1)

Engage load (load ON)

INPut 0 or INPut OFF (alternatively OUT 0)

Disengage load (load OFF)

SET PARAMETER LEVEL COMMANDS. Terminate command with ? to display parameter level.

CURRent <NR2>

Set Current level in Amperes

VOLTage <NR2>

Set Voltage level in Volts

POWer <NR2>

Set Power level in Watts

RESistance <NR2>

Set Resistance level in Ohms

CONDuctance <NR2>

Set Conductance level in Siemens

MEASUREMENT QUERIES.

MEASure:CURRent?

Return Load current in Amperes

MEASure:VOLTage?

Return Load voltage in Volts

MEASure:POWer?

Return Load power in Kilowatts

MEASure:ALL?

Return Load Power, Current and Voltage

PROTECTION COMMANDS. Terminate command with ? to display the protection setting for that mode.
Exceeding these user-defined protection levels disengages the UUT and displays fault indication (see
PAR. 3.3.1.)

CURRent:PROTection <NR2>

Set maximum Current level in Amperes