TABLE 2. POWER SUPPLY RATINGS AND SPECIFICATIONS

SPECIFICATION

DESCRIPTION

Input Voltage

85-265V a-c

(0 to 100% load, -10 to 65°C)

110-370V d-c

Polarity insensitive (0 to 100% load, -10 to 65°C) Safety
agency approval applies only to a-c input operation.

Input Source Frequency

50 to 60 Hz

47-440 Hz. (At 440 Hz the leakage current exceeds the
UL leakage safety specification limit).

Input Current: (Maximum Load At
25°C with Nominal Output Voltage)

4.4A rms max. (3.6A rms max for the 3.3V model)

100 - 120V a-c

2.2A rms max. (1.8A rms max for the 3.3V model)

200 - 240V a-c

Input Protection

A limiting resistor in series with a resistor fuse (in parallel with a thyristor circuit) reduces start-
up surge. Units are protected against shorts by an input fuse. Fuse value 10.0A At 250 Volts

Input Surge cold start,

interval > 30 sec

(1)

15A typ., 20A max. first surge

100 - 120V ac

30A typ., 40 max. first surge

200- 240 V ac

Leakage Current:

024mA typ., 0.3mA max. at 120V a-c, 60Hz (per IEC 950 and UL1950)
0.31mA typ., 0.38mA max. at 240V a-c, 60Hz (per IEC 950 and UL1950)

Power Factor

0.99 typical

rated output, rated input

Stabilization

Typical

Maximum

Source Effect (min - max) (85 to
132 V a-c, 170 to 265V a-c)

0.1%

(5 mV for 3.3V Model)

0.2%

(10 mV for 3.3V Model)

Load Effect, measured at sensing
terminals (0%-100% load change)

0.2%

(10mV for 3.3V Model)

0.4%

20mV for 3.3V Model)

Temperature Effect (–10° to 65°C)

0.5%

1.0%

Combined Effect (envelope,
Source, Load and Temperature)

±0.9%

±1.8%

Drift (from 1/2 to 8 hours at 25°C)

0.2%

0.5%

Remote Error Sensing:

Compensation up to 0.4 Volts per load wire (0.15 Volts for RKW 3.3-70K, 0.25 Volts for RKW
5-60K) (see Figure 8). Transient recovery specs may not be satisfied with this function used.

Transient Recovery
characteristic

excursion

±4% maximum

50% to 100% load,
transient time >50

µ

sec

recovery time

1 ms maximum

Start-up Time

350 msec maximum, 280 msec
typical.

100V a-c

210 msec maximum, 150 msec
typical.

240V a-c

Output Hold-up Time

30 msec typical, 20 msec mini-
mum.

100V a-c

40 msec typical, 20 msec mini-
mum.

240V a-c

Overvoltage Protection

When the Power Supply goes into an overvoltage condition, the output is cut OFF. To restart
(reset) the unit, it is necessary to remove the a-c input power, wait about 40 seconds, and then
to reconnect the a-c input power or to open and then reclose the RC terminals.

(1) First surge only, not including current flow into EMI filter