KEPCO RKW 300W Series Operator Manual User Manual

Page 5

Advertising
background image

RKW 300W 060110

3

Remote Control ON/OFF:

"High", 2.4V to 24V (or open), unit OFF- Fan Off ; "Low", 0.0V to 0.4V (or closed), unit ON.
Source current is 1.6mA maximum at low level, and sink current is 1.0 mA maximum at high
level. The ±RC terminals are isolated from the a-c input terminal and the DC output terminals.
When remote ON/OFF is not in use, ±RC terminals must be shorted (use shorting link sup-
plied) for unit to operate.

Operating Temperature:

-10 to 65°C (see figures 2 and 3)

Startup Temperature

-20 to -10°C (see Figure 2)

Storage Temperature:

-30°C to +75°C

Withstanding voltage : (at 15-35°C
ambient, 10-85% relative humidity)

2000Va-c for 1 minute. Cutout current is 20mA

Between input and ground

500Va-c for 1 minute. Cutout current is 100mA

Between output and ground

3000Va-c for 1 minute. Cutout current is 20mA

Between input and output

Insulation Resistance: (at 15-35°C
ambient, 10-85% relative humidity)

Between output and ground, input and ground, and input and output, 100 Megohms minimum
(500Vdc)

Humidity:

10% to 95% relative humidity, noncondensing, Wet Bulb tem-
perature</=35°C

operating and non-operating

Vibration:

5-10 Hz., 10mm amplitude,
10-200 Hz., acceleration 64.3ft./s

2

( 19.6m/s

2

) (2g)

non-operating, 1 hr. on each
of 3 axes, sweep time 10
minutes

Shock:
(non-operating, 1/2 sine pulse,
three shocks on each axis, Power
Supply is fixed on its bottom side)

Acceleration: 964.6ft./s

2

(294m/s

2

) (30g),

Pulse Duration: 11ms ± 5 msec

Safety:

All units designed to meet UL1950, CSA Electrical Bulletin 22.2 No.950-95 (certified by UL),
and TÜV Rheinland EN60950 (ambient temp.50°C max., 3.3V Model: 40°C max). Meets
Creepage and Clearance requirements of Dentori, Appendix 8. RKW 300W units are CE
marked per the Low Voltage Directive (LVD), 73/23/EEC and 93/68/EEC. [The standards do
not apply with DC input operation.]

EMI Conducted:

Designed to meet FCC Class B, VCCI-Class B, EN55011-B, EN55022-B.

EMI Radiated:

Designed to meet FCC Class B, VCCI-Class B, EN55011-B, EN55022-B.

Input current harmonics:

Designed to meet EN61000-3-2.

Immunity:

EN61000-6-2:1999

ESD immunity:

Designed to meet EN61000-4-2, level 4.

normal operation

Fast transient burst immunity:

Designed to meet EN61000-4-4 level 3.

normal operation

Surge immunity:

Designed to meet EN61000-4-5, level 4.

no damage

Power frequency magnetic field
immunity:

Designed to meet EN61000-4-8, level 4.

normal operation

Radiated field immunity:

Designed to meet EN61000-4-3 level 3.

normal operation

Conducted noise immunity:

Designed to meet EN61000-4-6 level 3.

normal operation

Voltage dips interruptions and
variations:

Designed to meet EN61000-4-11.

normal operation

Dimensions:

3.62 in. (92 mm) x 3.15 in. (80 mm) x 6.89 in. (175 mm)

Mounting:

Four No. M4 tapped holes on the sides and the bottom

Maximum Screw Penetration:

0.24 in. (6 mm)

Cooling:

Forced air flow - one fan

Frame Material/Cover Material:

Steel

Weight

3.3 lbs. (1.5Kg) typ., 3.97 lbs.(1.8 Kg) maximum

TABLE 2. POWER SUPPLY RATINGS AND SPECIFICATIONS (CONTINUED)

SPECIFICATION

DESCRIPTION

Advertising