KROHNE UFM 610P EN User Manual

Page 20

Advertising
background image

20

NOTE:
Site Zero is always the QUICK START data, the name cannot be changed.
Changing the data in any site is automatically saved when leaving this menu. Data will have to be re-entered if the input
is incorrect.

3.3.1

List sites

Selecting LIST SITES allows the user to view the names of up to
20 sites, numbers 1-10 appear first. Pressing ENTER at this point
will display sites from 11- 20. Press again and the display returns to
the VIEW/EDIT SITE DATA menu.

LIST SITES

1 site not named
2 site not named
3 site not named
4 site not named
5 site not named

yy-mm-dd hh:mm:ss

6 site not named
7 site not named
8 site not named
9 site not named

10 site not named

Press ENTER to continue

3.3.2

Site number

Site number allows the user to enter the number of the site data that you wish to be displayed. If the site has not been used then
no data would have been stored. It is possible to add application data at this point.

3.3.3

Site name

Site name allows the user to edit the site name. Use the scroll keys
to move the cursor to the letter/figure required and press ENTER to
select. Press 0 to return the instrument back to VIEW/EDIT SITE
DATA
. The new site name will appear on the display.

VIEW/EDIT SITE DATA yy-mm-dd hh:mm:ss

Use SCROLL to choose, ENTER to select,

for space, DELETE to clear, 0 to end

a

bcdefghijklmnopqrstuvwxyz0123456789

>

...............

<

3.3.4

Dimension units

Dimension units allows the user to switch between millimetres and inches. By doing this all the data in that particular site
number will also be converted. Pipe wall/lining thickness and Pipe wall/lining material can now be changed as required.
Lining material is ignored if a lining thickness was not entered. A selection of pipe wall/lining materials will be displayed when
these options are selected.

3.3.5

Fluid type

Fluid type allows the user to scroll through a selection of fluid types. Fluids not listed can be automatically measured by
selecting the Measure option in the QUICK START, but only when the pipe internal diameter is greater then 40 mm, Select
fluid type,
menu. When Other is selected the user must enter the propagation rate in m/s, this can be supplied by KROHNE or
found in the back of the manual under Liquid Sound Speeds on request.

Advertising