System Programming (cont’d)

6. Press the Group Description button to display the selector buttons "Daily

schedules" and "Schedule limits."

7. Press Daily schedules to display the selector buttons "Permanent" and

"Temporary."

8. Press Permanent or Temporary to display the current permanent or

temporary open/close schedule.

Hint: The system will start display with “today” (Mon-Sun).

9. Press More to step through the daily schedules and to the specific daily

schedule you would like to change.

10. Press Change to display the selector buttons "Open time" and "Close

time."

11. Press Open time or Close time to display the open or close schedule entry

screen.

12. Using the operating panel’s numeric keypad, enter the new open or close

time.

Example: 8:22 is entered as 0822.

13. Press AM or PM to complete your entry and to display the new open or

close schedule.

If Auto On/Off feature has been selected, see

Changing Auto On/Off

Schedule.

14. Press Change to display the Auto On/Off options, or press Quit to display

another daily operating schedule.

Guidelines for Changing Daily Operating Schedules:

• UUUU indicates Unscheduled; enter desired time. NNNN indicates Not

changeable; the schedule cannot be changed. Refer to your master system user.

• Open times cannot be later than closing times. Closing times cannot be earlier

than open times.

• Pressing Delete when changing an opening time will tell the system that no

opening will occur for that schedule. Persons without irregular access privilege
will be denied access or will create an Irregular Open Alarm.