TECHNICAL DATA

8

149

IFC 300

www.krohne.com

08/2010 - 4000069803 - MA IFC 300 R04 en

HART

HART

HART

HART

®

Description

HART

®

protocol via active and passive current output

HART

®

version: V5

Universal HART

®

parameter: completely integrated

Load

≥ 250 Ω at HART

®

test point;

Note maximum load for current output!

Multi-Drop operation

Yes, current output = 4 mA

Multi-Drop address adjustable in operation menu 1…15

Device drivers

Available for FC 375/475, AMS, PDM, FDT/DTM

Registration (HART

Communication Foundation)

Yes

Pulse or frequency output

Pulse or frequency output

Pulse or frequency output

Pulse or frequency output

Output data

Pulse output: volume flow, mass flow

Frequency output: volume flow, mass flow, diagnostic value, flow velocity, coil

temperature, conductivity

Function

Adjustable as pulse or frequency output

Pulse rate/frequency

Adjustable final value: 0.01...10000 pulse/s or Hz

Settings

Pulses per volume or mass unit or max. frequency for 100% flow

Pulse width: setting automatic, symmetric or fixed (0.05...2000 ms)

Operating data

Basic I/Os

Basic I/Os

Basic I/Os

Basic I/Os

Modular I/Os

Modular I/Os

Modular I/Os

Modular I/Os

Ex i I/Os

Ex i I/Os

Ex i I/Os

Ex i I/Os

Active

-

U

nom

= 24 VDC

-

f

max

in operating menu set

to

f

max

≤ 100 Hz:

I ≤ 20 mA

open:

I ≤ 0.05 mA

closed:

U

0, nom

= 24 V

at I = 20 mA

f

max

in operating menu set

to

100 Hz < f

max

≤ 10 kHz:

I ≤ 20 mA

open:

I ≤ 0.05 mA

closed:

U

0, nom

= 22.5 V

at I = 1 mA

U

0, nom

= 21.5 V

at I = 10 mA

U

0, nom

= 19 V

at I = 20 mA