Technical data, 2 technical data – KROHNE OPTIFLUX 7300 EN User Manual

Page 25

Advertising
background image

TECHNICAL DATA

6

25

OPTIFLUX 7300

www.krohne.com

01/2011 - 4001163301 - MA OPTIFLUX 7300 R01 en

6.2 Technical data

INFORMATION!

The following data is provided for general applications. If you require data that is more
relevant to your specific application, please contact us or your local representative.

Additional information (certificates, special tools, software,...) and complete product
documentation can be downloaded free of charge from the website (Download Center).

Measuring system

Measuring principle

Farady's law of induction

Application range

Continuous measurement of the volumetric flow rate of electrically

conductive liquids.

Measured value

Measured value

Measured value

Measured value

Primary measured value

Flow velocity

Secondary measured value

Volume flow, mass flow

Design

Features

Sandwich / flanged version with optimized flow tube

Modular construction

The measurement system consists of a flow sensor and a signal

converter. It is available as compact version only. More information

about the signal converter can be found in the documentation of the

signal converter.

Compact version

With IFC 300 C / CAP converter: OPTIFLUX 7300 C

Nominal diameter

DN25, 40, 50, 80, 100 / 1", 1½", 2", 3" and 4".

Measurement range

-12...+12 m/s / -40...+40 ft/s

Signal converter

Signal converter

Signal converter

Signal converter

Outputs / inputs

Current- (incl. HART

®

), pulse, frequency and/or status output, limit

switch and/or control input, current input (depends on the I/O

version)

Counters

2 (optional 3) internal counters with a max. of 8 counter places

(e.g. for counting volume and/or mass units)

Verification

Intergrated verification, diagnostic functions: measuring device,

process, measured value, empty pipe detection, stabilization.

Communication interfaces

Foundation Fieldbus, Profibus PA and DP, Modbus, HART

®

User interface

User interface

User interface

User interface

Display

LC Display, backlit white

Size: 128 x 64 pixel, corresponds to 59 x 31 mm / 2.32" x 1.22"

Display can be turned in steps of 90°

Ambient temperature below -25°C / -13°F, may effect the readability

of the display.

Operating elements

4 optical keys for operator control of the signal converter without

opening the housing.

Infrared interface for reading and writing all parameters with IR

interface (option) without opening the housing.

Advertising