Technical data – KROHNE OPTIFLUX 7300 EN User Manual
Page 28
6
TECHNICAL DATA
28
OPTIFLUX 7300
www.krohne.com
01/2011 - 4001163301 - MA OPTIFLUX 7300 R01 en
Materials
OPTIFLUX 7300 C - SW
OPTIFLUX 7300 C - SW
OPTIFLUX 7300 C - SW
OPTIFLUX 7300 C - SW
OPTIFLUX 7300 C - FL
OPTIFLUX 7300 C - FL
OPTIFLUX 7300 C - FL
OPTIFLUX 7300 C - FL
Sensor housing
Stainless steel AISI 304 (1.4306)
Stainless steel AISI 316 (1.4408)
Measuring tube
Ceramic
Ceramic
Flange
-
Stainless steel AISI 316 (1.4408)
Measuring electrodes
Non wetted, capacitive
Non wetted, capacitive
Grounding rings
Stainless steel, Hastelloy
®
C,
Titanium, Tantalum
-
Other materials on request.
-
Stud bolts and nuts
Standard: steel
-
Option: stainless steel, rubber,
centering sleeves
-
Gaskets
Gylon
®
, PTFE-PF 29,
Chemotherm
®
PTFE sealing rings
Other materials on request.
-
Signal converter housing
Standard: die-cast aluminium (polyurethane-coated)
Option: stainless steel 316 L (1.4408)
Process connections
OPTIFLUX 7300 C - SW
OPTIFLUX 7300 C - SW
OPTIFLUX 7300 C - SW
OPTIFLUX 7300 C - SW
OPTIFLUX 7300 C - FL
OPTIFLUX 7300 C - FL
OPTIFLUX 7300 C - FL
OPTIFLUX 7300 C - FL
EN 1092-1
Standard
Standard
Standard
Standard
DN100 in PN 16
DN100 in PN 16
DN25...80 in PN 40
DN25...80 in PN 40
Option
Option
Option
Option
Option: DN100 in PN 25
-
ASME
Standard
Standard
Standard
Standard
1...4" in 150 lb
1...4" in 150 lb
Option
Option
Option
Option
1...3" in 300 lb
1...3" in 300 lb
4" in 300 lb
Max. pressure is 30 bar / 435 psig
Electrical connection
General
Electrical connection is carried out in conformity with the VDE 0100
directive "Regulations for electrical power installations with line
voltages up to 1000 V" or equivalent national regulations.
Voltage
Standard
Standard
Standard
Standard
100...230 VAC (-15% / +10%), 50/60 Hz
Options
Options
Options
Options
24 VDC (-55% / +30% )
24 VAC/DC (AC: -15% / +10%, 50/60 Hz; DC: -25% / +30%)
Power consumption
AC: 22 VA
DC: 12 W
Cable entries
Standard: M20 x 1.5 (8...12 mm)
Option: ½" NPT, PF ½