1 Remove the 4 socket head screws at the bottom of the signal converter with a 5 mm Allen
wrench.
2 Remove the signal converter from the isolating chamber. Make sure that you do not damage
the 50 ohm wire.
3 Remove the 4 socket head screws at the bottom of the isolating chamber with a 5 mm Allen
wrench.
4 Remove the isolating chamber from the process connection. Make sure that you do not dam-
age the isolating chamber seal or the 50 ohm wire.
5 Disconnect the 50 ohm wire connector from the process conection with an 8 mm open-end
wrench.
Procedure 2B: How to remove the BM 100 signal converter (Ex-approved devices)
Figure 7-2: Procedure 2B: How to remove the BM 100 signal converter (Ex-approved devices)
WARNING!
De-energize the device and disconnect the electrical cables before you remove the signal
converter.
WARNING!
Make sure that you do not damage the isolating chamber seal or the 50 ohm wire.