Installation, 2 maximum surface temperature of the housing, 3 process pressure – KROHNE OPTIWAVE 6300C ATEX EN User Manual

Page 13

Advertising
background image

INSTALLATION

2

13

OPTIWAVE 6300 C

www.krohne.com

06/2010 - 4000482302 - AD ATEX OPTIWAVE 6300 R02 en

2.2.2 Maximum surface temperature of the housing

Equipment category 1 D: Ex iaD devices only
Equipment category 1/2 D, or 2 D: Ex iaD and Ex tD[iaD] devices only

2.2.3 Process pressure

Max. ambient temperature

Max. flange temperature

Max. surface
temperature

Drop and horn antennas

Drop and horn antennas

with the distance piece

[°C]

[°F]

[°C]

[°F]

[°C]

[°F]

[°C]

[°F]

+60

+140

+60

+140

+60

+140

+62

+143

+75

+167

+75

+167

+75

+167

+77

+170

+85

+185

+85

+185

+85

+185

+87

+188

+59

+138

+62

+143

+150

1

+302

1

≤+90

≤+194

-

-

+57

+134

+200

2

+302

2

≤+90

≤+194

1 Max. flange temperature is +100°C / +212°F, if the PP Drop antenna is used. Max. flange temperature is +150°C / +302°F, if the PTFE

Drop antenna is used.

2 Do not use the PP Drop antenna. Max. flange temperature is +150°C / +302°F, if the PTFE Drop antenna is used.

Equipment category

Allowable process pressure

[kPa]

[psi]

1 G or 1/2 G

80…110

1

11.6…16

1

Others

As per non-Ex device

As per non-Ex device

1 Atmospheric pressure

Advertising