10 technical data – KROHNE BATCHFLUX 5015 K EN User Manual

Page 43

Advertising
background image

Installation and operating instructions

43

BATCHFLUX


Part D Technical Data, block diagram

and measuring principle


10 Technical data

10.1 Flow during filling, and fill volume

Meter size

Optimum flowrate for filling

Filling times > 1.5 s,

filling volume .....

DN mm inches

ml/s

US Gal/min

ml

US Gal

2.5

1

/

10

3 -

10 0.048 -

0.159

10

0.003

4

1

/

8

10 -

30 0.159 -

0.476

20

0.005

6

1

/

4

20 -

60 0.317 -

0.951

40

0.011

10

3

/

8

60 -

200 0.951 -

3.170

100

0.026

15

1

/

2

150 -

500 2.378 -

7.925

200

0.053

25 1

400 -

1200 6.340 -

19.020

600

0.159

32 1

1

/

4

650 -

2250 10.300 -

35.663

975

0.257

40 1

1

/

2

1000 -

3000 15.850 -

47.551

1500

0.396


10.2 Flowmeter

Meter sizes

with venturi measuring tube

DN 2.5, 4, 6, 10, 15, 25, 40 and

1

/

10

",

1

/

8

",

1

/

4

",

3

/

8

",

1

/

2

", 1",1

1

/

2

"

with straight tube (option)

DN 15, 32 and

1

/

2

", 1

1

/

4

"

Connection

sandwich (flangeless) type with precisely defined sealing faces,

centering devices and metallic stop face

Electrical conductivity

≥ 5 µS/cm (≥ 20 µS/cm for demineralized cold water)

Ambient temperature

Process temperature

-25 to +40 °C / -13 to +104 °F

-60 to +140 °C / -76 to +356 °F

-25 to +60 °C / -13 to +140 °F

-60 to + 60 °C / -76 to +140 °F

(information on higher provided on request)

steam cleaning up to +150 °C / +302 °F

Temperature shock resistance Temperature rising Temperature falling

sudden change

∆T = 120 °C = 248 °F

∆T = 90 °C = 194 °F

Temperature gradient

1 K/s

Operating pressure

40 bar / 580 psig, dependent on gaskets used

(10 bar / 145 psig for DN 15, 32 and

1

/

2

", 1

1

/

4

"

with straight measuring tube)

Electrode design fused-in-place

electrodes

Protection category

IP 67, equivalent to NEMA 6

(EN 60 529/IEC 529)

(overall device, incl. signal converter)

Materials of construction
Housing

stainless steel 1.4408 or 1.4404

Measuring tube

fine-grain-stabilized, high-density HiTec ceramics,

purity 99.7

% Al

2

O

3

(+ZrO

2

), CIP- and SIP-proof

Electrodes Cermet

Cover seal

EPDM

10

Advertising