3 Start-up

3.1 Switch-on and measurement

Before powering the system, please check that it has been correctly installed according
to Sect. 1 and 2.

The flowmeter is delivered ready for operational use. All operating data have
been factory set in accordance with your specifications.
Please refer to Sect. 3.2 “factory settings”.

Power the unit, and the flowmeter will immediately start process flow
measurement.

Basic version, signal converter IFC 090 / B

A light emitting diode (LED) under the cover of the electronic section shows the
measurement status. Remove the cover using the special wrench.
LED flashing . . .

green:

measurement correct, everything all right.

green / red: momentary overdriving of outputs

and/or A/D converter.

red:

fatal error, parameter error or hardware fault,
please consult factory.

Refer to Sect. 6.2 for operator control of the “basic version”.

Display version, signal converter IFC 090 / D

When powered, the display shows in succession: START UP and READY.
This is followed by display of the current flow rate and/or the current totalizer count
on either a continuous or alternating basis, depending on the setting under Fct. 1.04.

Refer to Sect. 4 and 5 for operator control of the “display version”.