KROHNE OPTIMASS with MFC 05x EN User Manual

Page 56

Advertising
background image

Installation and Operating Instructions OPTIMASS

55

4.3.1 How to enter programming mode

To start:

Display Comments

→ Press

Fct. 1
OPERATION
or

If this appears, see box: ”Function of the keys ” in 4.3.


CodE 1
---------

If this appears on the display, set the 9-keystroke Supervisor CodE
1 .
Factory setting:

→ → → ↵ ↵ ↵ ↑ ↑ ↑

1

st

- 8

th

place

(key)

CodE 1
∗∗∗∗∗∗∗∗-

Each keystroke acknowledged by " * " in display.

9

th

place

(key)

Fct. 1
OPERATION

If this appears, see box: ”Function of the keys ” in 4.3.

XXXXX

CODE WRONG

A wrong Supervisor CodE 1 was keyed in. Press any key and set
the correct 9-keystroke Supervisor CodE 1.*


* If correct code is not known, note number given (XXXXX) and contact KROHNE for further instructions
regarding decoding.

4.3.2 How to terminate Programming mode

To terminate:

Display Comments

Press

↵ 1-5

times

Fct (1).0
OPERATION

Press

↵ 1...5 times until the cursor is under the extreme left menu

column. (Fct. 1, 2, 3, 4 or 5).

+ 12.3
kg/min
or

If no changes have been made to the system’s configuration return
directly to the measurement mode.

(ACCEPT

YES)

Changes have been detected. Press

↵ to accept these changes.

or

(ACCEPT NO)

Press

↵ to reject changes and return directly to measurement

mode.
or

(GO BACK)

Press

↵ to return to the menus, Fct. 1.(0) to make further changes

Return to measurement mode.

Advertising