Installation – KROHNE OPTIWAVE 7300 IECEx User Manual

Page 10

Advertising
background image

2

INSTALLATION

10

OPTIWAVE 7300 C

www.krohne.com

10/2010 - 4000176502 - AD IECEX OPTIWAVE7300 R02 en

EPL Gb:
Ex ia and Ex d[ia] devices - with the 4...20 mA output option

Zone 20: Ex iaD devices only
Zone 21/20: Ex iaD and Ex tD[iaD] devices

Temperature

class

Ambient temperature

Flange temperature

Hygienic antennas

Drop and horn

antennas

Drop and horn

antennas with the

distance piece

[°C]

[°F]

[°C]

[°F]

[°C]

[°F]

[°C]

[°F]

T6

-40…+57

-40…+134

-40…+57

-40…+134

-40…+57

-40…+134

-50…+60

1

-58…+140

1

-40…+50

-40…+122

-40…+47

-40…+116

-40…+51

-40…+124

-50…+85

1

-58…+185

1

T5

-40…+72

-40…+161

-40…+72

-40…+161

-40…+72

-40…+161

-50…+75

1

-58…+167

1

-40…+65

-40…+149

-40…+62

-40…+143

-40…+66

-40…+151

-50…+100

1

-58…+212

1

T4

2

-40…+80

-40…+176

-40…+80

-40…+176

-40…+80

-40…+176

-50…+85

1

-58…+185

1

-40…+76

-40…+169

-40…+74

-40…+165

-40…+79

-40…+174

-50…+100

1

-58…+212

1

-40…+73

-40…+163

-40…+70

-40…+158

-40…+74

-40…+165

-50…+110

1

-58…+230

1

-40…+66

-40…+151

-40…+60

-40…+140

-40…+68

-40…+154

-50…+135

1

-58…+275

1

T3

3

-40…+62

-40…+143

-40…+54

-40…+129

-40…+64

-40…+147

-50…+150

1

-58…+302

1

-

-

-

-

-40…+57

-40…+134

-50…+180

1

-58…+356

1

-

-

-

-

-40…+52

-40…+125

-50…+200

1

-58…+392

1

1 Min. -50°C / -58°F, if an EPDM gasket is used. Min. -20°C / -4°F, if a Kalrez® 6375 gasket is used. Min. -40°C / -40°F, if an FKM/FPM

gasket is used. Min. -30°C / -22°F, if a Metaglas® feedthrough is used. Min. -50°C / -58°F, if a PEI feedthrough is used.

2 Max. flange temperature is +100°C / +212°F, if the PP Drop antenna used
3 Do not use this temperature class for the PP Drop antenna. Max. flange temperature is +150°C / +302°F, if the PTFE Drop antenna or

Hygienic antenna are used.

Ambient temperature

Flange temperature

[°C]

[°F]

[°C]

[°F]

-40…+85

-40…+185

-50…+200

1

-58…+392

1

1 Max. flange temperature is +100°C / +212°F, if PP Drop antenna used. Max. flange temperature is +150°C / +302°F, if the PTFE Drop or

the Hygienic antenna is used. Min. -50°C / -58°F, if an EPDM gasket is used. Min. -20°C / -4°F, if a Kalrez® 6375 gasket is used. Min. -
40°C / -40°F, if an FKM/FPM gasket is used. Min. -30°C / -22°F, if a Metaglas® feedthrough is used. Min. -50°C / -58°F, if a PEI
feedthrough is used.

Advertising