9. OPTIONAL ACCESSORIES

Model 8004 and 8008 (Multi-Tran)
These models help Model 2434 to measure current greater than
1000A or to make measurement on a large bus-bar or conductor.

(1)Set the Range Selector Switch to "100A".
(2)As shown, open the jaws and close them over the pickup coil

of Model 8004 or Model 8008.

(3)Clamp on a conductor with Model 8004 or Model 8008.
(4)Take the reading and multiply it by 10.

Note: Model 8004 and Model 8008 cannot be used for leakage current

m e a s u r e m e n t . F o r d e t a i l e d s p e c i f i c a t i o n s , r e f e r t o t h e
instruction manual for Model 8004 or Model 8008.

M-2434

M-8004
M-8008

Pickup Coil

Conductor

Transformer
jaws

10

M-8004
M-8008

Max. Conductor Size

60mm in diameter

100mm in diameter

Measuring

Range

0∼1000A

Current Transformation

Ratio

10:1