Continuity Test (Resistance Test) Ranges(IEC 61557-4)
Ranges

Measuring range to keep

Maximum percentage

operating error

operating error

3

0.2

- 3

±30%

The influencing variations used for calculating the operating error are denoted
as follows:

Temperature

: 0

C and 35

C

Supply voltage : 6.4V to 10.4V
Position

: Reference position ±90

※Prior to measurement, apply 0-Adjustment at each position.

AC Voltage Warning:

Warning range

0-600V

Accuracy

±5% of scale length

Input impedance

1.2M

Typical Number of measurements (central tendency for supply voltage up to

6.0V)
Insulation Resistance Ranges:

1M

at 1000V Range

Approx. 1,400 times min.

0.5M

at 500V Range

Approx. 3,500 times min.

0.25M

at 250V Range

Approx. 5,500 times min.

Continuity Test (Resistance Test) Ranges:

1

at 3

Range

Approx. 1,500 times min.

Applicable Standards

IEC 61010-1

Overvoltage CAT.III 600V Pollution Degree 2

IEC 61010-2-31

Safety requirements for hand-held probe assemblies

IEC 61557-1/2/4

Measuring equipment for low voltage distribution systems

IEC 61326-1

EMC

IEC 60529 (IP54) Dust & drip proof

Operating Temperature & Humidity:

0 - 40°C, relative humidity up to 85%

Storage Temperature & Humidity:

-10 - 50°C, relative humidity up to 75%

Insulation Resistance :

More than 50M

at 1000V DC between electrical circuit

and housing case

Withstand Voltage: 5550V AC for one minute between electrical circuit and

housing case

Overload Protection Insulation resistance ranges:

1000V Range

1200V (DC+AC p-p) for 10 seconds

500V Range

600V (DC+AC p-p) for 10 seconds

250V Range

300V (DC+AC p-p) for 10 seconds

Continuity ranges:

3

/500

Range 280V (DC+AC p-p) for 10 seconds

AC Voltage Warning:

1200V (DC+AC p-p) for 10 seconds

Dimensions:

106(L) x 160(W) x 72(D) mm approx.

Weight:

560g approx. (including batteries)

Power Source:

6 x 1.5V battery type R6P ,1.5V AA or equivalent

Accessories

Test Probe MODEL7122

x 1 set

Pouch for test Probe

x 1

Shoulder strap

x 1

R6P batteries

x 6

Spare fuse F500mA/600V x 1