0 specifications – Metex 2200R ORP Analyzer/Controller User Manual

Page 4

Advertising
background image

Model 2200R

Page 2

2.0 SPECIFICATIONS

DISPLAY:
4 x 7 segment ½” LED Display

MEASURING RANGES:

ORP: 0 to 1000mV or -1000mV to +1000mV


POWER REQUIREMENTS:
Standard: 98-132 Vac, 50/60 Hz (less than 5 VA)
Optional: 196-264 Vac, 50/60 Hz (less than 5 VA)

23-26Vdc (nominal current 150mA)

AMBIENT CONDITIONS:
-30 to 50°C (-22 to 122°F)
0 to 90% R.H. non-condensing

CONTROL RELAY:
5A 115/230 Vac, 5A 30 Vdc SPDT

Selectable to activate in response to rising or falling
process

Fully adjustable setpoint and deadband
Manual Override Auto / Off / On for Relay A
Cycling Feature: On time 0-600sec Off time 0-600sec
Normal or Fail Safe operation

ALARM RELAY:
5A 115/230 Vac, 5A 30 Vdc SPDT

Programmable to activate at high and low alarm
setpoints

Deadband fixed at 2% of Full Scale

Normal or Fail Safe Operation


RELAY INDICATORS:

Three individual LEDs indicate status of the two control
relays and the alarm relay.

ANALOG OUTPUTS:
Non Isolated 0-1mA, 100 ohms maximum load
Non Isolated 0-5Vdc, 1000 ohms minimum load
Isolated 4-20mA, 800 ohms maximum load

Range Expand: The analog outputs can be scaled to
represent any segment of the full scale of the
instrument. Minimum segment is 10% of Full Scale.
Output Hold: The analog outputs are automatically
placed on hold when the unit is placed in any menu
mode.

SENSOR-TO-ANALYZER DISTANCE:

Differential Probe (R60) 3000 feet maximum
Conventional combination probe 25 feet (an
AquaMetrix Series 101 preamplifier is required for
distances greater than 25 feet)


CALIBRATION:

Two point













TEMPERATURE READOUT:

Automatic 0°C to 100°C (32°F to 212°F) If probe has
temperature compensation


SYSTEM ERROR:

A LED indicates a system alarm. The alarm relay can
be programmed to activate upon system memory loss.


DIAGNOSTICS:
Invalid entries are identified by respective flashing

LEDs. When a status error occurs, press CALL to
obtain the status error number, which corresponds to a
fault as described in the Status Fault Table.

TEST:
Display value and analog outputs can be set manually

to any value for testing and diagnostic purposes. This
feature allows the operation of the control relays, alarm
relay, and outputs to be tested independently of
process value.


SAFETY AND SECURITY:

Non-volatile

memory (EEPROM)

Password protected if enabled
Watch-dog timer monitors microprocessor

Instrument automatically returns to on line operation if
accidentally left in menu mode. (This feature may be
field disabled if desired.)


SENSITIVITY: 0.1% of span


STABILITY: 0.1% of span per 24 hrs. non-cumulative.

NON-LINEARITY: 0.1% of span

REPEATABILITY: 0.1% of span or better

TEMPERATURE DRIFT:
Zero: 0.01% of span per °C
Span: 0.01% of span per °C

RESPONSE TIME:
0.5 second to 90% of value upon step change

ENCLOSURE:

NEMA 4X molded fiberglass reinforced polyester
enclosure with four 1/2" conduit holes and mounting
feet for surface mount. A NEMA 4 plug is provided for
one hole.

MOUNTING CONFIGURATIONS:
Standard is surface mount
Optional panel mount hardware Part No. C35-68
Optional pipe mount hardware Part No. C35-69

NET WEIGHT: 3 1/2 lb. (1.6 kg)


Approvals: CSA