Specifications – Precision Control Systems 1032 User Manual

Page 9

Advertising
background image

Model 1032

7 of 9

Part No. 5000095-1011-6 6/13/2003

SPECIFICATIONS

Control Mode
Command Signal

Control Range
Linearity
Zero and Span Adj.
Current Limit Adj.
Isolation

Cooling
Mounting

Line voltage

Load Current
Diagnostic Indicators

Physical

Environment

dv/dt & Transient

Voltage Protection

Heat dissipation
Recommended Fusing

Single-phase; Phase-angle; RMS value of the voltage applied to the load
Signal

Impedance

0-5Vdc

100K

0-10Vdc

200K

1 to 20 K Pot.

200K

4-20mA

300 ohms

6 to 97% of line voltage, typical.
RMS load voltage is linear within 2% of span of the command signal.
User adjustable over a range of 20% of span
User adjustable over a range from 20% to 110% of rated current
Dielectric strength input/line & load voltage/heatsink: 2500 V(

RMS

)

Insulation resistance input/line & load voltage/heatsink: 10

10

ohms.

Maximum capacitance input to output:

8 pf

Convection
Must be mounted on vertical surface with fins vertical. Units may be

mounted adjacent to each other. Heat sink is electrically isolated from

circuit and power.
120, 240, 480 & 575Vac +10%,-20% 50/60 Hertz

Consult factory for other voltages.
10, 20, 30, 40 & 70 Amps A.C. 50/60 Hertz.
The intensity of the 'SSR DRIVE' LED varies proportionally to the

Voltage applied to the load.

The intensity of the 'LOAD CURRENT' LED varies as a function of the

load current.

These LED's provide a quick and safe means to check controller

operation
Weight: 10 thru 40 amps: 5 lbs. max., 70 amps: 9 lbs. max.

Dimensions: See installation drawings, pages 3 & 4.
Operating:

0 to 55

o

C (32 to 131

o

F)

Storage:

-40 to 80

o

C (-40 to 176

o

F)

Humidity:

0 to 95% Non-condensing

200 volts/usec minimum

A dv/dt snubber and a metal oxide varistor (MOV) are provided to

protect against high frequency transients (dv/dt) and voltage spikes.
1.5 watt per amp of controlled current
Special semiconductor fuses are not required. It is recommended that

the controller and load be protected with fast acting class "T" fuses

such as Bussmann type JJS or JJN fuses. Control Concepts

maintains an inventory of fuses and fuse holders for your convenience.

Advertising