Adjustments, See adjustments, Section – Precision Control Systems 3629C User Manual

Page 22: Dre g n a, Om d c9 26 3 le

Advertising
background image

MODEL 3629C

18

04/10/2007

ADJUSTMENTS

The zero and span potentiometers are factory set, and generally do not require further adjustment.

If adjustments become necessary, the following procedure should be followed.

If you are using RMS feedback, you must use a true RMS meter for these measurements.

1. Set the command signal to minimum and adjust the zero potentiometer until the output is zero. If this pot is set

incorrectly, the output of the controller may not be linear with respect to the command signal, or, the controller may be

unable to shut off completely.

2. Set the command signal to maximum and adjust the span potentiometer until the output is at the desired maximum

value. If this pot is set incorrectly, the output of the controller may not be linear with respect to the command signal, or,

the controller may be unable to reach full output.

3. The span and zero adjustments may interact, therefore it may be necessary to repeat steps 1 and 2.

Current limit potentiometer adjustment.

To monitor the Current Limit Adjustment, apply the negative lead of your multimeter to terminal 14 of the command

connector, and the positive lead to terminal 17. See

Figure 22

.

Rotating the Current Limit potentiometer clockwise increases the value to which the load current is limited. Negative 1Volt

= 100% of frame current.

Over Current Trip potentiometer adjustment.

To monitor the Over Current trip Adjustment, apply the negative lead of your multimeter to terminal 14 of the command

connector, and the positive lead to terminal 18. See

Figure 21

.

Rotating the Over Current Trip potentiometer clockwise increases the value at which the Over Current Trip circuit will

activate. Positive 1Volt = 100% of frame current.

(+5) CW

OVER

CURRENT

RELAY

SHORTED

SCR

RELAY

READY

COMMON

RESET

I LIMIT

EXT. FB.

(+) W

O.C.T.

(- ) CCW

-5 VOLT

TI

MI

L

OR

EZ

NA

PS

TC

O

C

L

O

RT

N

O

C

N

O
C

ST

PE

D

RE

G

N

A

H

GI

H

E

G

AT

L

OV

O

M
D

C9

26

3

LE

Figure 29. Lid of 3629C showing adjustment locations.

Advertising