Figure 19, For connections, Feedback type. (see – Precision Control Systems 1029C User Manual

Page 19: Figure 18, Connector (see, Adjustments (continued)

Advertising
background image

MODEL 1029C

15

10/19/2007

ADJUSTMENTS (Continued)

X
X

X

X

Installed

for power

feedback

only

Run Span Pot.
Run Zero Pot.

Idle Span Pot.
Idle Zero Pot.

THESE FOUR POTS, AND

THE CURRENT LIMIT POT

ARE MOUNTED ON THE

BACK SIDE OF THE BOARD

TO SHOW THROUGH LID

P2 FeedbackSelector

. See Figure 18

DO NOT CHANGE ADJUSTMENTS
ON POTS MARKED WITH AN ‘X’

DO NOT CHANGE ADJUSTMENTS
ON POTS MARKED WITH AN ‘X’

Current Limit Pot. (shows through lid.)
Over Current Trip

SUMMING JUNCTION

EXTERNAL F.B.

CURRENT F.B.

VOLTAGE F.B

POWER F.B.

Figure 18. P2 Details

FEEDBACK SELECTION

Figure 17. 1029C circuit board showing adjustment locations.

CW

W

RUN (+)

COM(-) CCW

IDLE (+) W

SHOR

TED

SCR REL

AY

OVER

CURREN

T

REL

AY

FB. BK.

COMMON

RESE

T

RUN/IDLE

+5V

I. METER

V. METER

1

2

3

4

5

6

7

8

9

10

11

12

13

14

15

16

17

18

COMMON

EXTERNAL FEEDBACK

INPUT CONNECTIONS

0-100mA or 0-5 V

Figure 19. External feedback connections.

Advertising